Distribution network topology identification method based on SMOTE-TCN

With the construction of new power system, distributed energy and charging piles are connected in large quantities, which makes the topology of distribution network more complicated. At present, there is a lack of effective topology identification methods for distribution network stations. In this paper, a time convolutional neural network is proposed to identify the dependency relationship between the user and the station area, it provides the basis for judging the three-phase unbalance of the platform area. In view of the problems of low quality and imbalance data, SMOTE data processing algorithm is used to deal with the imbalance data. The experimental results show that: The combination of SMOTE data processing and temporal convolutional neural network algorithm can effectively identify the user's station area. The average identification accuracy rate of all stations reached 89.31%, and the recall rate reached 89.36%.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/isneet64164.2024.10956012
Citations
1
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distribution network topology identification method based on SMOTE-TCN

Jiancheng Su, Junxiang Huang, Zheng Ruan, Ziqi Zhang et al.
1 citations
Smart Grid and Power Systems
0.21
article

Distribution network topology identification method based on SMOTE-TCN

Jiancheng Su, Junxiang Huang, Zheng Ruan, Ziqi Zhang, Xuefeng Wang, Yu Zou
article en
1 citations

Abstract

With the construction of new power system, distributed energy and charging piles are connected in large quantities, which makes the topology of distribution network more complicated. At present, there is a lack of effective topology identification methods for distribution network stations. In this paper, a time convolutional neural network is proposed to identify the dependency relationship between the user and the station area, it provides the basis for judging the three-phase unbalance of the platform area. In view of the problems of low quality and imbalance data, SMOTE data processing algorithm is used to deal with the imbalance data. The experimental results show that: The combination of SMOTE data processing and temporal convolutional neural network algorithm can effectively identify the user's station area. The average identification accuracy rate of all stations reached 89.31%, and the recall rate reached 89.36%.

China Southern Power Grid (China) (CN)
Climate action
Openalex Percentile: Top 43%
Smart Grid and Power Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Distribution network topology identification method based on SMOTE-TCN — Jiancheng Su, Junxiang Huang, et al. · (2024) | TGRS Research Map | TGRS