Modeling and simulation of an effectual triangular slotted UWB flexible antenna for breast cancer detection and healthcare monitoring

With refinements in electromagnetics, diverse medical applications have evolved to detect diseases efficaciously. Breast cancer, a dominant cause of mortality among women worldwide, necessitates early diagnosis and screening for timely medical intervention. This research establishes the design, simulation, and analysis of an advanced triangular slotted circular flexible Ultra-wideband (UWB) antenna optimized for breast cancer detection and healthcare monitoring. The proposed antenna employs an extensive frequency range of 2.95 GHz to 24.2 GHz, accomplishing an impressive impedance bandwidth of 156%. It authenticates directional and omnidirectional radiation patterns with compact dimensions of 46.3 × 52.6 × 1.076 mm³. Key aspects divulge a resonance frequency at 14.35 GHz with a significant input reflection coefficient of -37.8 dB. The antenna achieves a peak gain of 3.16 dB at 5.8 GHz, with efficiencies of 59.56% and 66.88% at 5.8 GHz and 4.48 GHz, respectively. A meticulous case study involving SAR evaluation confirms the antenna's safe exposure levels. For a flat human phantom, SAR values are 0.774 W/kg at 13.5 GHz and 0.712 W/kg at 14.35 GHz for 10 gm of tissue. For the breast phantom model, SAR values are 0.201 W/kg at 11.4 GHz and 0.152 W/kg at 14.35 GHz for 10 gm of tissue. Besides that, the antenna's flexible design promises an excellent execution under several bending conditions, making it ideal for wearable applications. These findings establish the antenna as an efficient solution for breast cancer detection and healthcare monitoring, combining safety, flexibility, and the aptness to ameliorate early diagnosis while lowering mortality rates. Wearable antennas are pivotal for advanced healthcare applications. This section presents the literature and discusses the work related to flexible UWB antenna designed for breast cancer detection and healthcare monitoring, tackling challenges in early diagnosis and patient care.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-04-17
DOI
https://doi.org/10.1371/journal.pone.0320806
Citations
5
Primary Topic
Antenna Design and Analysis
Type
article
Field-Weighted Citation Impact
24.97
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling and simulation of an effectual triangular slotted UWB flexible antenna for breast cancer detection and healthcare monitoring

Manish Sharma, A. N. Singh, Kanhaiya Sharma, Bülent Yılmaz et al.
5 citations
PLoS ONE
Antenna Design and Analysis
24.97
article

Modeling and simulation of an effectual triangular slotted UWB flexible antenna for breast cancer detection and healthcare monitoring

Manish Sharma, A. N. Singh, Kanhaiya Sharma, Bülent Yılmaz, Vinod Kumar Singh, Rajesh Kumar Dwivedi
article en
5 citations

Abstract

With refinements in electromagnetics, diverse medical applications have evolved to detect diseases efficaciously. Breast cancer, a dominant cause of mortality among women worldwide, necessitates early diagnosis and screening for timely medical intervention. This research establishes the design, simulation, and analysis of an advanced triangular slotted circular flexible Ultra-wideband (UWB) antenna optimized for breast cancer detection and healthcare monitoring. The proposed antenna employs an extensive frequency range of 2.95 GHz to 24.2 GHz, accomplishing an impressive impedance bandwidth of 156%. It authenticates directional and omnidirectional radiation patterns with compact dimensions of 46.3 × 52.6 × 1.076 mm³. Key aspects divulge a resonance frequency at 14.35 GHz with a significant input reflection coefficient of -37.8 dB. The antenna achieves a peak gain of 3.16 dB at 5.8 GHz, with efficiencies of 59.56% and 66.88% at 5.8 GHz and 4.48 GHz, respectively. A meticulous case study involving SAR evaluation confirms the antenna's safe exposure levels. For a flat human phantom, SAR values are 0.774 W/kg at 13.5 GHz and 0.712 W/kg at 14.35 GHz for 10 gm of tissue. For the breast phantom model, SAR values are 0.201 W/kg at 11.4 GHz and 0.152 W/kg at 14.35 GHz for 10 gm of tissue. Besides that, the antenna's flexible design promises an excellent execution under several bending conditions, making it ideal for wearable applications. These findings establish the antenna as an efficient solution for breast cancer detection and healthcare monitoring, combining safety, flexibility, and the aptness to ameliorate early diagnosis while lowering mortality rates. Wearable antennas are pivotal for advanced healthcare applications. This section presents the literature and discusses the work related to flexible UWB antenna designed for breast cancer detection and healthcare monitoring, tackling challenges in early diagnosis and patient care.

PLoS ONEVol. 20(4)
Gulf University for Science & Technology (KW), Chhatrapati Shahu Ji Maharaj University (IN), Symbiosis International University (IN), JRE Group of Institutions (IN), Chitkara University (IN)
Good health and well-being
Openalex Percentile: Top 1%
Antenna Design and Analysis
24.97
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.