Optimal Method of Minimum Start-Up Mode for Conventional Units Considering Multi-Factor Constraints

With the increasing proportion of external power supply and the installed capacity of new energy, the start-up mode for conventional units of the receiver power grid network is gradually decreasing, and the minimum start-up sequence needs to be optimized in order to maintain the stability of the power grid. In this paper, the key factors affecting the minimum start-up units are extracted, and the quantitative indicators of the multi-feed short-circuit ratio of new energy, the electrical distance between the generator and the weak node, and the dynamic reactive power response of the generator are extracted, which are used to characterize the support ability of the power grid unit start-up mode to the system voltage stability. Then, with the goal of optimizing the above indicators, considering the operation constraints of conventional units and new energy units, the minimum start-up optimization model of the power grid is established to determine the minimum start-up sequence of the power grid. Finally, taking the actual power grid in China as an example, the simulation proves the correctness and effectiveness of the proposed method.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/isneet64164.2024.10956112
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Method of Minimum Start-Up Mode for Conventional Units Considering Multi-Factor Constraints

Pengfei Gao, Tianle Li, Hao Ma, Bin Zhao et al.
Induction Heating and Inverter Technology
article

Optimal Method of Minimum Start-Up Mode for Conventional Units Considering Multi-Factor Constraints

Pengfei Gao, Tianle Li, Hao Ma, Bin Zhao, Yuzhi Wang, Qianyu Wu
article en

Abstract

With the increasing proportion of external power supply and the installed capacity of new energy, the start-up mode for conventional units of the receiver power grid network is gradually decreasing, and the minimum start-up sequence needs to be optimized in order to maintain the stability of the power grid. In this paper, the key factors affecting the minimum start-up units are extracted, and the quantitative indicators of the multi-feed short-circuit ratio of new energy, the electrical distance between the generator and the weak node, and the dynamic reactive power response of the generator are extracted, which are used to characterize the support ability of the power grid unit start-up mode to the system voltage stability. Then, with the goal of optimizing the above indicators, considering the operation constraints of conventional units and new energy units, the minimum start-up optimization model of the power grid is established to determine the minimum start-up sequence of the power grid. Finally, taking the actual power grid in China as an example, the simulation proves the correctness and effectiveness of the proposed method.

State Grid Corporation of China (China) (CN)
Openalex Percentile: Top 71%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimal Method of Minimum Start-Up Mode for Conventional Units Considering Multi-Factor Constraints — Pengfei Gao, Tianle Li, et al. · (2024) | TGRS Research Map | TGRS