Predicted vs. Observed Prosthesis–Patient Mismatch After Surgical Aortic Valve Replacement

<i>Background and Objectives</i>: Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) is associated with worse clinical outcomes and worse valve durability. The aim of this retrospective single-center study was to evaluate the consistency between predicted PPM (PPMp) and measured PPM (PPMm) after SAVR with three different bioprostheses. <i>Materials and Methods</i>: We analyzed data of all consecutive patients who underwent surgical aortic valve replacement with Magna Ease, Intuity, and Inspiris Resilia bioprostheses (Edwards Lifesciences, Irvine, CA, USA) at our institution. PPM was defined if EOAi ≤ 0.85 cm<sup>2</sup>/m<sup>2</sup>. PPMm was determined by institutional echo lab-measured EOAi on discharge-day echocardiogram. PPMp was assessed using reference values for each valve model and size indexed to BSA based on height, weight, prosthesis type, and size. For the overall population and for the three valve types we evaluated the sensitivity, specificity, positive predicted value, negative predicted value, and accuracy of PPMp. Furthermore, the consistency between PPMm and PPMp were evaluated according to prosthesis type, size, stent internal diameter (ID), and true ID. <i>Results</i>: A total of 1323 patients underwent SAVR; complete hemodynamic data were available for 872 patients, who represent the population of our study. Magna Ease, Intuity, and Inspiris Resilia were implanted in 446 (51.1%), 341 (39.1%), and 85 (9.7%) patients, respectively. In 635 out of 872 cases (72.8%), PPMp was consistent with PPMm (Magna Ease: 321/446, 72%; Inspiris Resilia: 58/85, 68.2%; Intuity: 256/341, 75%). Overall, the sensitivity, specificity, positive predicted value, negative predicted value, and accuracy of PPMp were 0.26, 0.83, 0.24, 0.84, and 0.73, respectively (Magna Ease: 0.21, 0.82, 0.3, 0.8, and 0.72; Inspiris Resilia: 0.11, 0.82, 0.14, 0.79, and 0.68; Intuity: 0.45, 0.78, 0.19, 0.93, and 0.75). <i>Conclusions</i>: The consistency between PPMp and PPMm was suboptimal. We did not observe differences between PPMp and PPMm among different valve types. Discordance between PPMp and PPMm was more evident in smaller valve sizes. When implanting small valves, the evaluation of PPMp should be used with caution to avoid unexpected PPMm.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-04-17
DOI
https://doi.org/10.3390/medicina61040743
Citations
3
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
4.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predicted vs. Observed Prosthesis–Patient Mismatch After Surgical Aortic Valve Replacement

Giorgia Cibin, Chiara Tessari, Irene Cao, Valentina Lombardi et al.
3 citations
Medicina
Cardiac Valve Diseases and Treatments
4.16
article

Predicted vs. Observed Prosthesis–Patient Mismatch After Surgical Aortic Valve Replacement

Giorgia Cibin, Chiara Tessari, Irene Cao, Valentina Lombardi, Assunta Fabozzo, Emma Bergonzoni, Andrea Francavilla, Darío Gregori, Augusto D’Onofrio, Gino Gerosa, Giulia Lorenzoni
article en
3 citations

Abstract

<i>Background and Objectives</i>: Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) is associated with worse clinical outcomes and worse valve durability. The aim of this retrospective single-center study was to evaluate the consistency between predicted PPM (PPMp) and measured PPM (PPMm) after SAVR with three different bioprostheses. <i>Materials and Methods</i>: We analyzed data of all consecutive patients who underwent surgical aortic valve replacement with Magna Ease, Intuity, and Inspiris Resilia bioprostheses (Edwards Lifesciences, Irvine, CA, USA) at our institution. PPM was defined if EOAi ≤ 0.85 cm<sup>2</sup>/m<sup>2</sup>. PPMm was determined by institutional echo lab-measured EOAi on discharge-day echocardiogram. PPMp was assessed using reference values for each valve model and size indexed to BSA based on height, weight, prosthesis type, and size. For the overall population and for the three valve types we evaluated the sensitivity, specificity, positive predicted value, negative predicted value, and accuracy of PPMp. Furthermore, the consistency between PPMm and PPMp were evaluated according to prosthesis type, size, stent internal diameter (ID), and true ID. <i>Results</i>: A total of 1323 patients underwent SAVR; complete hemodynamic data were available for 872 patients, who represent the population of our study. Magna Ease, Intuity, and Inspiris Resilia were implanted in 446 (51.1%), 341 (39.1%), and 85 (9.7%) patients, respectively. In 635 out of 872 cases (72.8%), PPMp was consistent with PPMm (Magna Ease: 321/446, 72%; Inspiris Resilia: 58/85, 68.2%; Intuity: 256/341, 75%). Overall, the sensitivity, specificity, positive predicted value, negative predicted value, and accuracy of PPMp were 0.26, 0.83, 0.24, 0.84, and 0.73, respectively (Magna Ease: 0.21, 0.82, 0.3, 0.8, and 0.72; Inspiris Resilia: 0.11, 0.82, 0.14, 0.79, and 0.68; Intuity: 0.45, 0.78, 0.19, 0.93, and 0.75). <i>Conclusions</i>: The consistency between PPMp and PPMm was suboptimal. We did not observe differences between PPMp and PPMm among different valve types. Discordance between PPMp and PPMm was more evident in smaller valve sizes. When implanting small valves, the evaluation of PPMp should be used with caution to avoid unexpected PPMm.

MedicinaVol. 61(4)
University of Rome Tor Vergata (IT), University of Padua (IT)
Responsible consumption and production
Openalex Percentile: Top 6%
Cardiac Valve Diseases and Treatments
4.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.