Characterization of CLLBC scintillation detector response to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si67.svg" display="inline" id="d1e1266"><mml:mi>γ</mml:mi></mml:math>-rays and neutrons

The dual-mode elpasolite scintillation material CLLBC ( Cs 2 LiLaBr 4.8 Cl 1.2 :Ce) is capable of measuring both γ -rays and neutrons. The neutron detection capability spans from thermal energies up to about 10 MeV, making these detectors attractive options for studying prompt fission neutron spectra (PFNS). In this work, a comprehensive characterization of CLLBC detectors is performed. Three CLLBC detectors were characterized, in addition to three LaBr 3 :Ce and two LaBr 3 :Ce,Sr for comparison. For the best-performing CLLBC detector, the results indicate an energy resolution of 3.7% at E γ = 662 keV and an intrinsic timing resolution of 1.2 ns (FWHM) above E γ = 1 MeV using 60 Co. A γ -neutron separation figure-of-merit of 2.7 is obtained by means of pulse-shape discrimination. Tagged neutron time-of-flight measurements were conducted using a 241 Am 9 Be neutron source, by coincident detection of the 4.44 MeV γ -ray and the neutron, to determine the intrinsic neutron detection efficiency between 2–6 MeV. Neutron detection efficiencies of about 0.2% for the 6 Li(n,t) 4 He reaction and 1% for three types of (n,n′) reactions were obtained. Two of three investigated CLLBC detectors exhibit an energy peak asymmetry, resulting in worse performance, indicating scintillator quality issues and motivating further investigation. Future studies are anticipated using the 252 Cf(sf) prompt fission neutron spectrum to determine neutron efficiencies for a wider range of neutron energies. Although observed in a previous study, neutron detection via 35 Cl(n,p) 35 S was not identified in this work but is planned to be determined using quasi-monoenergetic neutrons generated at the JRC MONNET facility.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-04-18
DOI
https://doi.org/10.1016/j.nima.2025.170470
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
1.88
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of CLLBC scintillation detector response to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si67.svg" display="inline" id="d1e1266"><mml:mi>γ</mml:mi></mml:math>-rays and neutrons

Alessandro Borella, M. Macías, S. Oberstedt, Ali Al-Adili et al.
1 citations
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Radiation Detection and Scintillator Technologies
1.88
article

Characterization of CLLBC scintillation detector response to <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si67.svg" display="inline" id="d1e1266"><mml:mi>γ</mml:mi></mml:math>-rays and neutrons

Alessandro Borella, M. Macías, S. Oberstedt, Ali Al-Adili, Riccardo Rossa, W. Geerts, A. Oberstedt, M. Lantz, M. Vidali, Cristiano Lino Fontana, Elias Arnqvist
article en
1 citations

Abstract

The dual-mode elpasolite scintillation material CLLBC ( Cs 2 LiLaBr 4.8 Cl 1.2 :Ce) is capable of measuring both γ -rays and neutrons. The neutron detection capability spans from thermal energies up to about 10 MeV, making these detectors attractive options for studying prompt fission neutron spectra (PFNS). In this work, a comprehensive characterization of CLLBC detectors is performed. Three CLLBC detectors were characterized, in addition to three LaBr 3 :Ce and two LaBr 3 :Ce,Sr for comparison. For the best-performing CLLBC detector, the results indicate an energy resolution of 3.7% at E γ = 662 keV and an intrinsic timing resolution of 1.2 ns (FWHM) above E γ = 1 MeV using 60 Co. A γ -neutron separation figure-of-merit of 2.7 is obtained by means of pulse-shape discrimination. Tagged neutron time-of-flight measurements were conducted using a 241 Am 9 Be neutron source, by coincident detection of the 4.44 MeV γ -ray and the neutron, to determine the intrinsic neutron detection efficiency between 2–6 MeV. Neutron detection efficiencies of about 0.2% for the 6 Li(n,t) 4 He reaction and 1% for three types of (n,n′) reactions were obtained. Two of three investigated CLLBC detectors exhibit an energy peak asymmetry, resulting in worse performance, indicating scintillator quality issues and motivating further investigation. Future studies are anticipated using the 252 Cf(sf) prompt fission neutron spectrum to determine neutron efficiencies for a wider range of neutron energies. Although observed in a previous study, neutron detection via 35 Cl(n,p) 35 S was not identified in this work but is planned to be determined using quasi-monoenergetic neutrons generated at the JRC MONNET facility.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1076
Uppsala University (SE), European Commission (BE), Belgian Nuclear Research Centre (BE), Extreme Light Infrastructure - Nuclear Physics (RO)
Openalex Percentile: Top 18%
Radiation Detection and Scintillator Technologies
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies