Structural Performance and Failure Mechanisms in Bend Loading of Steel-Aerated Concrete Fire Wall Composite Panels

Modularised wall panels are increasingly used in building and construction. A new double-skin composite (DSC) wall system technology uses clinch seams to combine two roll-formed open section profiles into a hollow steel shell that is then filled with a light-weight concrete foam and can provide a fire-rated DSC solution for use in commercial and high-rise buildings. One important material parameter for the application is the panel performance in wind loading. This study presents a first fundamental analysis of the structural behaviour of the new DSC wall panel relevant to wind loading. For this, 3-point and 4-point bending tests combined with in situ camera analysis are performed and complimented with the analysis of seam strength and the concrete material parameters. The experimental results provide the first experimental evidence that the aerated concrete core material of the DSC panel only has a minor effect on the wall performance in bending. Most of the bending loads are absorbed by the tensile and compressive deformation of the steel outer shell and the shear deformation near the clinch seam. In this way, failure at maximum load is not initiated by concrete cracking but by steel sheet buckling or a mixed failure mode that combines steel buckling and seam opening.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-04-17
DOI
https://doi.org/10.3390/buildings15081338
Citations
1
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Performance and Failure Mechanisms in Bend Loading of Steel-Aerated Concrete Fire Wall Composite Panels

Matthias Weiß, Peng Zhang, Xinyu Hu, Michael P. Pereira
1 citations
Buildings
Fire effects on concrete materials
0.95
article

Structural Performance and Failure Mechanisms in Bend Loading of Steel-Aerated Concrete Fire Wall Composite Panels

Matthias Weiß, Peng Zhang, Xinyu Hu, Michael P. Pereira
article en
1 citations

Abstract

Modularised wall panels are increasingly used in building and construction. A new double-skin composite (DSC) wall system technology uses clinch seams to combine two roll-formed open section profiles into a hollow steel shell that is then filled with a light-weight concrete foam and can provide a fire-rated DSC solution for use in commercial and high-rise buildings. One important material parameter for the application is the panel performance in wind loading. This study presents a first fundamental analysis of the structural behaviour of the new DSC wall panel relevant to wind loading. For this, 3-point and 4-point bending tests combined with in situ camera analysis are performed and complimented with the analysis of seam strength and the concrete material parameters. The experimental results provide the first experimental evidence that the aerated concrete core material of the DSC panel only has a minor effect on the wall performance in bending. Most of the bending loads are absorbed by the tensile and compressive deformation of the steel outer shell and the shear deformation near the clinch seam. In this way, failure at maximum load is not initiated by concrete cracking but by steel sheet buckling or a mixed failure mode that combines steel buckling and seam opening.

BuildingsVol. 15(8)
Deakin University (AU)
Openalex Percentile: Top 27%
Fire effects on concrete materials
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.