Gas gaps and chambers quality control of improved Resistive Plate Chambers

In preparation for the Phase-II upgrade for the High-Luminosity LHC program, 72 improved Resistive Plate Chambers (iRPC) will be installed in the third and fourth endcap disks of the Compact Muon Solenoid detector during the annual technical stop 2024. This new generation of RPC detectors will operate in a low-angle momentum (extending RPC coverage from pseudorapidity | η | = 1.9 to 2.4), in a high radiation environment, and will bring a better space and time resolution for this challenging region. To ensure proper performance, iRPC chambers undergo a series of quality control (QC) tests at each stage of the assembly chain. These tests include QC1 for the basic components, QC2 for chamber elements such as gaps and cooling, QC3 for evaluating the full chamber performance after production, which includes noise, efficiency, current, lastly QC4 for the final validation of the chambers. In this work we present the different QC stages and discuss test results for the newly built iRPCs at the assembly sites.

Authors

Institutions

Publication Details

Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Published
2025-04-17
DOI
https://doi.org/10.1016/j.nima.2025.170484
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gas gaps and chambers quality control of improved Resistive Plate Chambers

A. Santoro, L. Balleyguier, I. Lomidze, Neal Patrick Smith et al.
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
Radiation Detection and Scintillator Technologies
article

Gas gaps and chambers quality control of improved Resistive Plate Chambers

A. Santoro, L. Balleyguier, I. Lomidze, Neal Patrick Smith, X. Chen, E. Asilar, Andrés Cabrera, H. Kou, C. Uribe Estrada, J. Eysermans, H. Castilla-Valdez, N. Zaganidis, E. Zareian, K. Skovpen, I. Crotty, A. Sánchez-Hernández, E. Shumka, A. Samalan, C. Ávila, P. Iaydjiev, B.C. Ferreira, H. R. Hoorani, F. Marujo da Silva, M. Shopova, P. Cao, E. Coelho, Yeonsu Ryou, C. Combaret, A. Braghieri, A. Dimitrov, A. Luciol, D. Ramos, A. Petrov, K. Mota Amarilo, Kyong Sei Lee, G. Galbit, L. Mundim, F. Loddo, G. Iaselli, J. Zhao, P. Salvini, L. Litov, R. Hadjiiska, T. J. Kim, I. Pedraza, V. Amoozegar, B. Pavlov, B. Boghrati, E. M. Da Costa, G. Sultanov, Yasaman Hosseini, G. A. Alves, Qingfeng Hou, B. El-mahdy, J.P. Pinheiro, D.L. Ramirez Guadarrama, Na Wang, P. Vitulo, C. Riccardi, Y. Assran, Ashfaq Ahmad, D. Piccolo, S. Bianco, Magdi A. Ali, M. Ebrahimi, P. Paolucci, Fabiola Vazquez Valencia, F. Fienga, A. Radi, S. J. Qian, G. Grenier, C. Florez, M. Gouzevitch, J. A. Reyes Vega, I. Bagaturia, Zhenan Liu, F. Carnevali, J. Goh, G. Pugliese, Diego Andres Barbosa Trujillo, Z. Tsamalaidze, P. Montagna, R. Aly, O. Kemularia, M. Tytgat, S. Choi, B. Hong, D. De Jesus Damião, M. Thiel, Mehar Ali Shah, S. Meola, M. Abbrescia, R. Gomes De Souza, S. Fonseca De Souza, Y. Lee, R. López-Fernández, H. Nogima, M. Ramirez-García, M. A. Mahmoud, S. Buontempo, M. Mohammadi Najafabadi, T. De Andrade rangel Monteiro, S. Muhammad, J. Shin, L. Mirabito, W. Tromeur, M. I. Asghar, W. Diao, W. X. Gong, J. Song, M. Barroso Ferreira Filho, L. Benussi, P. Petkov, L. Lista, N. De Filippis, F. E. Neri Huerta, А. Александров, F. Esfandi
article en

Abstract

In preparation for the Phase-II upgrade for the High-Luminosity LHC program, 72 improved Resistive Plate Chambers (iRPC) will be installed in the third and fourth endcap disks of the Compact Muon Solenoid detector during the annual technical stop 2024. This new generation of RPC detectors will operate in a low-angle momentum (extending RPC coverage from pseudorapidity | η | = 1.9 to 2.4), in a high radiation environment, and will bring a better space and time resolution for this challenging region. To ensure proper performance, iRPC chambers undergo a series of quality control (QC) tests at each stage of the assembly chain. These tests include QC1 for the basic components, QC2 for chamber elements such as gaps and cooling, QC3 for evaluating the full chamber performance after production, which includes noise, efficiency, current, lastly QC4 for the final validation of the chambers. In this work we present the different QC stages and discuss test results for the newly built iRPCs at the assembly sites.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentVol. 1077
Vrije Universiteit Brussel (BE), British University in Egypt (EG), University of Dundee (GB), Ghent University (BE), Universidade do Estado do Rio de Janeiro (BR), Centro Brasileiro de Pesquisas Físicas (BR), Benemérita Universidad Autónoma de Puebla (MX)
Openalex Percentile: Top 90%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.