Saliva-Sensing Dental Floss: An Innovative Tool for Assessing Stress via On-Demand Salivary Cortisol Measurement with Molecularly Imprinted Polymer and Thread Microfluidics Integration

On-demand dental-floss-based point-of-care platform is developed for the noninvasive and real-time quantification of salivary cortisol utilizing redox-molecule embedded molecularly imprinted polymer structures and thread microfluidics. Herein, we explore the high-surface-area graphene-based electrode substrate for electrochemically synthesizing selective cortisol MIPs and integrate it with thread microfluidics to build a highly sensitive cortisol-sensing platform for stress monitoring. This platform uses flossing to collect and transport saliva to a flexible electrochemical sensor via capillary microfluidics, where cortisol, a stress biomarker, is measured. This strategy allowed us to detect cortisol as low as 0.048 pg mL<sup>-1</sup> in real-time with a detection range of 0.10-10,000 pg mL<sup>-1</sup> (<i>R</i><sup>2</sup> = 0.9916). The saliva-sensing dental floss provides results within 11-12 min. The thread-based microfluidic design minimizes interference and ensures consistent repeatability when testing both artificial and actual human saliva samples, yielding 98.64-102.4% recoveries with a relative standard deviation of 5.01%, demonstrating high accuracy and precision. For the human saliva sample (as part of the stress study), the platform showed a high correlation (<i>r</i> = 0.9910) against conventional ELISA assays. Combined with a wireless readout, this saliva floss offers a convenient way to monitor daily stress levels. It can be extended to detect other critical salivary biomarkers with high sensitivity and selectivity in complex environments.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-04-17
DOI
https://doi.org/10.1021/acsami.5c02988
Citations
10
Primary Topic
Salivary Gland Disorders and Functions
Type
article
Field-Weighted Citation Impact
11.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Saliva-Sensing Dental Floss: An Innovative Tool for Assessing Stress via On-Demand Salivary Cortisol Measurement with Molecularly Imprinted Polymer and Thread Microfluidics Integration

Ayanna K. Thomas, Nafize Ishtiaque Hossain, Atul Sharma, Sameer Sonkusale
10 citations
ACS Applied Materials & Interfaces
Salivary Gland Disorders and Functions
11.64
article

Saliva-Sensing Dental Floss: An Innovative Tool for Assessing Stress via On-Demand Salivary Cortisol Measurement with Molecularly Imprinted Polymer and Thread Microfluidics Integration

Ayanna K. Thomas, Nafize Ishtiaque Hossain, Atul Sharma, Sameer Sonkusale
article en
10 citations

Abstract

On-demand dental-floss-based point-of-care platform is developed for the noninvasive and real-time quantification of salivary cortisol utilizing redox-molecule embedded molecularly imprinted polymer structures and thread microfluidics. Herein, we explore the high-surface-area graphene-based electrode substrate for electrochemically synthesizing selective cortisol MIPs and integrate it with thread microfluidics to build a highly sensitive cortisol-sensing platform for stress monitoring. This platform uses flossing to collect and transport saliva to a flexible electrochemical sensor via capillary microfluidics, where cortisol, a stress biomarker, is measured. This strategy allowed us to detect cortisol as low as 0.048 pg mL<sup>-1</sup> in real-time with a detection range of 0.10-10,000 pg mL<sup>-1</sup> (<i>R</i><sup>2</sup> = 0.9916). The saliva-sensing dental floss provides results within 11-12 min. The thread-based microfluidic design minimizes interference and ensures consistent repeatability when testing both artificial and actual human saliva samples, yielding 98.64-102.4% recoveries with a relative standard deviation of 5.01%, demonstrating high accuracy and precision. For the human saliva sample (as part of the stress study), the platform showed a high correlation (<i>r</i> = 0.9910) against conventional ELISA assays. Combined with a wireless readout, this saliva floss offers a convenient way to monitor daily stress levels. It can be extended to detect other critical salivary biomarkers with high sensitivity and selectivity in complex environments.

ACS Applied Materials & InterfacesVol. 17(17)
Tufts University (US)
National Science Foundation, Uniformed Services University of the Health Sciences, Congressionally Directed Medical Research Programs
Openalex Percentile: Top 1%
Salivary Gland Disorders and Functions
11.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.