Testing a large size triple GEM detector for the first station of the CBM-Muon Chambers with a high-intensity gamma source at GIF++ under large-area illumination

Abstract The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime choices for the upcoming Compressed Baryonic Matter (CBM) experiment at the Facility of Antiproton and Ion Research, Germany. However, operating them under these demanding conditions requires a systemic study at the highest incident particle flux. To this end, we have conducted extensive tests on a real-size triple GEM detector module with the high-intensity gamma flux using the Cs-137 source at the upgraded Gamma Irradiation Facility (GIF++) at Conseil Européen pour la Recherche Nucléaire (CERN). The detector response, particularly regarding the gain and efficiency of muon detection, was studied extensively with and without a gamma source in a free-streaming mode using self-triggered electronics. This configuration will be necessary for the CBM experiment since it will observe unprecedented event rates of about 10 MHz for Au-Au collisions. The analysis reveals an alignment between the expected and observed value of gain and efficiency with an increasing intensity of gamma flux at the operating voltage. The test results demonstrate that the large-size GEM detector prototype can handle elevated gamma rates of approximately 17.25 MHz/cm 2 without significantly impacting its performance or suffering irreversible damage.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-04-01
DOI
https://doi.org/10.1088/1748-0221/20/04/p04022
Citations
1
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
1.87
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Testing a large size triple GEM detector for the first station of the CBM-Muon Chambers with a high-intensity gamma source at GIF++ under large-area illumination

Ekata Nandy, V. Singhal, Anand Kumar Dubey, S. Chattopadhyay et al.
1 citations
Journal of Instrumentation
Particle Detector Development and Performance
1.87
article

Testing a large size triple GEM detector for the first station of the CBM-Muon Chambers with a high-intensity gamma source at GIF++ under large-area illumination

Ekata Nandy, V. Singhal, Anand Kumar Dubey, S. Chattopadhyay, Pawan Kumar Sharma, A. Agarwal, J. Saini, Vinod Singh Negi, Z. Ahammed, Chandrasekhar Ghosh, D. Emschermann, S. Chattopadhay
article en
1 citations

Abstract

Abstract The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime choices for the upcoming Compressed Baryonic Matter (CBM) experiment at the Facility of Antiproton and Ion Research, Germany. However, operating them under these demanding conditions requires a systemic study at the highest incident particle flux. To this end, we have conducted extensive tests on a real-size triple GEM detector module with the high-intensity gamma flux using the Cs-137 source at the upgraded Gamma Irradiation Facility (GIF++) at Conseil Européen pour la Recherche Nucléaire (CERN). The detector response, particularly regarding the gain and efficiency of muon detection, was studied extensively with and without a gamma source in a free-streaming mode using self-triggered electronics. This configuration will be necessary for the CBM experiment since it will observe unprecedented event rates of about 10 MHz for Au-Au collisions. The analysis reveals an alignment between the expected and observed value of gain and efficiency with an increasing intensity of gamma flux at the operating voltage. The test results demonstrate that the large-size GEM detector prototype can handle elevated gamma rates of approximately 17.25 MHz/cm 2 without significantly impacting its performance or suffering irreversible damage.

Journal of InstrumentationVol. 20(04)
Variable Energy Cyclotron Centre (IN), GSI Helmholtz Centre for Heavy Ion Research (DE), Homi Bhabha National Institute (IN)
Openalex Percentile: Top 14%
Particle Detector Development and Performance
1.87
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.