Development of optimised protocols for paediatric whole-body computed tomography examinations: a figure-of-merit approach
The estimated ED<sub>WB</sub> from this study were lower than established values. The selected protocols are recommended for newborns and children (1-7 years) using the GE Revolution CT and Siemens SOMATOM Definition Edge CT scanners.