A New Control Scheme for Load Side Converter of Stand‐Alone Doubly Fed Induction Generator

ABSTRACT In this paper, a simple and novel control strategy for a stand‐alone doubly fed induction generator (DFIG)‐based wind turbine under combined unbalanced and non‐linear loads is presented. These types of loads cause negative sequence and harmonics in the stator voltage and current, which leads to power and torque oscillation. As a solution, a new control strategy is presented in the load side converter (LSC) which compensates for the stator current and voltage, simultaneously. The instantaneous active and reactive power theory is used to extract all of the harmonic components of the stator current and voltage. Based on the presented papers, the main task of LSC is to compensate for the stator current. In our proposed method, the per‐unit values of stator voltage harmonics are added to the LSC's reference signals. Because the resulted reference signals are sinusoidal, the proportional‐resonant (PR) controller is used to track the sinusoidal references. Therefore, the stator voltage is compensated in addition to the stator current for all types of loads, and the rotor side converter is only required to control the voltage amplitude and frequency. The harmonic components are extracted by algebraic equations. So, the system has a fast dynamic response, which is suitable for practical implementation. To validate the presented control strategy, simulation and experimental implementation for a 5.5 kW DFIG are done in the paper.

Authors

Institutions

Publication Details

Journal
IET Power Electronics
Published
2025-01-01
DOI
https://doi.org/10.1049/pel2.70036
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Control Scheme for Load Side Converter of Stand‐Alone Doubly Fed Induction Generator

E. Fallah, Mojtaba Pourjafari
1 links
IET Power Electronics
Wind Turbine Control Systems
article

A New Control Scheme for Load Side Converter of Stand‐Alone Doubly Fed Induction Generator

E. Fallah, Mojtaba Pourjafari
article en

Abstract

ABSTRACT In this paper, a simple and novel control strategy for a stand‐alone doubly fed induction generator (DFIG)‐based wind turbine under combined unbalanced and non‐linear loads is presented. These types of loads cause negative sequence and harmonics in the stator voltage and current, which leads to power and torque oscillation. As a solution, a new control strategy is presented in the load side converter (LSC) which compensates for the stator current and voltage, simultaneously. The instantaneous active and reactive power theory is used to extract all of the harmonic components of the stator current and voltage. Based on the presented papers, the main task of LSC is to compensate for the stator current. In our proposed method, the per‐unit values of stator voltage harmonics are added to the LSC's reference signals. Because the resulted reference signals are sinusoidal, the proportional‐resonant (PR) controller is used to track the sinusoidal references. Therefore, the stator voltage is compensated in addition to the stator current for all types of loads, and the rotor side converter is only required to control the voltage amplitude and frequency. The harmonic components are extracted by algebraic equations. So, the system has a fast dynamic response, which is suitable for practical implementation. To validate the presented control strategy, simulation and experimental implementation for a 5.5 kW DFIG are done in the paper.

IET Power ElectronicsVol. 18(1)
University of Guilan (IR)
Openalex Percentile: Top 94%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.