Comparing Auto-Machine Learning and Expert-Designed Models in Diagnosing Vitreomacular Interface Disorders
<b>Background:</b> The vitreomacular interface (VMI) encompasses a group of retinal disorders that significantly impact vision, requiring accurate classification for effective management. This study aims to compare the effectiveness of an expert-designed custom deep learning (DL) model and a code free Auto Machine Learning (ML) model in classifying optical coherence tomography (OCT) images of VMI disorders. <b>Materials and Methods:</b> A balanced dataset of OCT images across five classes-normal, epiretinal membrane (ERM), idiopathic full-thickness macular hole (FTMH), lamellar macular hole (LMH), and vitreomacular traction (VMT)-was used. The expert-designed model combined ResNet-50 and EfficientNet-B0 architectures with Monte Carlo cross-validation. The AutoML model was created on Google Vertex AI, which handled data processing, model selection, and hyperparameter tuning automatically. Performance was evaluated using average precision, precision, and recall metrics. <b>Results:</b> The expert-designed model achieved an overall balanced accuracy of 95.97% and a Matthews Correlation Coefficient (MCC) of 94.65%. Both models attained 100% precision and recall for normal cases. For FTMH, the expert model reached perfect precision and recall, while the AutoML model scored 97.8% average precision, and 97.4% recall. In VMT detection, the AutoML model showed 99.5% average precision with a slightly lower recall of 94.7% compared to the expert model's 95%. For ERM, the expert model achieved 95% recall, while the AutoML model had higher precision at 93.9% but a lower recall of 79.5%. In LMH classification, the expert model exhibited 95% precision, compared to 72.3% for the AutoML model, with similar recall for both (88% and 87.2%, respectively). <b>Conclusions:</b> While the AutoML model demonstrated strong performance, the expert-designed model achieved superior accuracy across certain classes. AutoML platforms, although accessible to healthcare professionals, may require further advancements to match the performance of expert-designed models in clinical applications.
Authors
- Andrzej E. Grzybowski (ORCID: https://orcid.org/0000-0002-3724-2391)
- Ozan Gökkan (ORCID: https://orcid.org/0000-0002-0339-6990)
- Ceren Durmaz Engin (ORCID: https://orcid.org/0000-0001-5797-6467)
- M. Alper Selver (ORCID: https://orcid.org/0000-0002-8445-0388)
- Mustafa Kayabaşı (ORCID: https://orcid.org/0000-0003-2059-0696)
- Seher Köksaldı (ORCID: https://orcid.org/0000-0001-8235-4088)
- Ufuk Beşenk
Institutions
- Izmir University (TR)
- Dokuz Eylül University (TR)
- Sivas State Hospital (TR)
- İzmir Demokrasi Üniversitesi
- University of Warmia and Mazury in Olsztyn (PL)
Publication Details
- Journal
- Journal of Clinical Medicine
- Published
- 2025-04-17
- DOI
- https://doi.org/10.3390/jcm14082774
- Citations
- 2
- Primary Topic
- Retinal Imaging and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 2.72