Calcium and Microhardness Quantification in Healthy and Fluorotic Dentin Conditioned with a Self-Etching System: An In Vitro Study

<b>Background:</b> Dental fluorosis can affect the micromorphology of dentin, a fact that could present constraints relating to the structural, mechanical, and chemical stability of dentin when it is demineralized in operative maneuvers. <b>Introduction:</b> The aim of this article is to quantify the amount of calcium and the microhardness of both a healthy and a fluorotic dentin through conditioning with a two-step self-etching system (Optibond Versa, Kerr, CA, USA). <b>Methods:</b> Dentin samples were obtained from healthy molars diagnosed with mild, moderate, and severe fluorosis. The amount of calcium was quantified utilizing an atomic absorption spectrophotometer. The hardness was evaluated using a Vickers durometer. Two dentin samples from each study group were examined using scanning electron microscopy (SEM). <b>Results:</b> A one-way analysis of variance (ANOVA) and Tukey-Kramer test were applied as post hoc tests for determining the differences in calcium values between the study groups and to show the difference in the hardnesses evaluated. The Student's t-test was applied to related samples. The level of significance was set at <i>p</i> < 0.05. Statistically significant results were obtained for the amount of calcium and microhardness of the healthy dentin group. The SEM images demonstrated irregular etching patterns in the fluorotic dentin, indicating potential bonding challenges. <b>Conclusion:</b> In conclusion, there is a lower amount of calcium and a significant reduction in microhardness in healthy dentin when applying the self-etching system compared to fluorotic dentin. Fluorotic dentin is more resistant to demineralization, which may influence adhesive bonding strategies. Clinicians should consider adjusting conditioning protocols for optimal adhesion in fluorotic teeth.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-04-17
DOI
https://doi.org/10.3390/dj13040168
Citations
1
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.68
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calcium and Microhardness Quantification in Healthy and Fluorotic Dentin Conditioned with a Self-Etching System: An In Vitro Study

Carlos Enrique Cuevas‐Suárez, Alejandro Rivera-Gonzaga, Louis Hardan, Naji Kharouf et al.
1 citations
Dentistry Journal
Dental materials and restorations
1.68
article

Calcium and Microhardness Quantification in Healthy and Fluorotic Dentin Conditioned with a Self-Etching System: An In Vitro Study

Carlos Enrique Cuevas‐Suárez, Alejandro Rivera-Gonzaga, Louis Hardan, Naji Kharouf, Ahmed A. Holiel, Youssef Haïkel, Nicolas Nassar, Rim Bourgi, Ana Josefina Monjarás‐Ávila, Norma Verónica Zavala-Alonso
article en
1 citations

Abstract

<b>Background:</b> Dental fluorosis can affect the micromorphology of dentin, a fact that could present constraints relating to the structural, mechanical, and chemical stability of dentin when it is demineralized in operative maneuvers. <b>Introduction:</b> The aim of this article is to quantify the amount of calcium and the microhardness of both a healthy and a fluorotic dentin through conditioning with a two-step self-etching system (Optibond Versa, Kerr, CA, USA). <b>Methods:</b> Dentin samples were obtained from healthy molars diagnosed with mild, moderate, and severe fluorosis. The amount of calcium was quantified utilizing an atomic absorption spectrophotometer. The hardness was evaluated using a Vickers durometer. Two dentin samples from each study group were examined using scanning electron microscopy (SEM). <b>Results:</b> A one-way analysis of variance (ANOVA) and Tukey-Kramer test were applied as post hoc tests for determining the differences in calcium values between the study groups and to show the difference in the hardnesses evaluated. The Student's t-test was applied to related samples. The level of significance was set at <i>p</i> < 0.05. Statistically significant results were obtained for the amount of calcium and microhardness of the healthy dentin group. The SEM images demonstrated irregular etching patterns in the fluorotic dentin, indicating potential bonding challenges. <b>Conclusion:</b> In conclusion, there is a lower amount of calcium and a significant reduction in microhardness in healthy dentin when applying the self-etching system compared to fluorotic dentin. Fluorotic dentin is more resistant to demineralization, which may influence adhesive bonding strategies. Clinicians should consider adjusting conditioning protocols for optimal adhesion in fluorotic teeth.

Dentistry JournalVol. 13(4)
Universidad Autónoma del Estado de Hidalgo (MX), Inserm (FR), Saint Joseph University (LB), Autonomous University of San Luis Potosí (MX), Beirut Arab University (LB), Université de Strasbourg (FR), Alexandria University (EG)
Openalex Percentile: Top 21%
Dental materials and restorations
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.