Optimization of PET Image Reconstruction for Enhanced Image Quality in Various Tasks Using a Conventional PET Scanner

Positron emission tomography (PET) imaging requires high‐quality yet rapid reconstruction to ensure clinical effectiveness, as these reconstructions enable timely and accurate diagnosis, guide treatment decisions, and reduce the risk of delayed interventions in critical clinical settings. This study introduces a deep learning‐based method that employs conditional generative adversarial networks (cGANs) for direct sinogram‐to‐image PET reconstruction. A dual approach was used: simulation experiments with Zubal phantoms, which provided a controlled and reproducible environment to test the reconstruction accuracy and robustness, and validation with real patient datasets, ensuring the method’s applicability and effectiveness in clinical settings. The primary objective was to evaluate the ability of the cGAN‐based method to enhance image quality, reduce noise, and improve reconstruction speed compared to conventional algorithms, such as maximum likelihood expectation maximization (MLEM) and total variation (TV). The methodology involved training a U‐net‐based generator and a whole‐image discriminator iteratively to reconstruct PET images with superior resolution and accuracy. Key outcome measures included bias, variance, structural similarity index (SSIM), and relative root mean square error (rRMSE), as these metrics effectively quantify image fidelity, noise levels, and structural accuracy, which are critical for evaluating the clinical reliability and precision of reconstructed PET images. The results showed that the proposed method achieved significant improvements in image clarity, noise suppression, and computational efficiency, outperforming the traditional techniques. These findings highlight the potential of cGAN‐based reconstruction in improving diagnostic accuracy and clinical workflow.

Authors

Institutions

Publication Details

Journal
Journal of Electrical and Computer Engineering
Published
2025-01-01
DOI
https://doi.org/10.1155/jece/8108611
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of PET Image Reconstruction for Enhanced Image Quality in Various Tasks Using a Conventional PET Scanner

Zaid H. Al-Sawaff, Raid Rafi Omar Al-Nima, Ahmed Sabeeh Yousif, Zahraa M. Rashid
2 citations
Journal of Electrical and Computer Engineering
Medical Imaging Techniques and Applications
2.72
article

Optimization of PET Image Reconstruction for Enhanced Image Quality in Various Tasks Using a Conventional PET Scanner

Zaid H. Al-Sawaff, Raid Rafi Omar Al-Nima, Ahmed Sabeeh Yousif, Zahraa M. Rashid
article en
2 citations

Abstract

Positron emission tomography (PET) imaging requires high‐quality yet rapid reconstruction to ensure clinical effectiveness, as these reconstructions enable timely and accurate diagnosis, guide treatment decisions, and reduce the risk of delayed interventions in critical clinical settings. This study introduces a deep learning‐based method that employs conditional generative adversarial networks (cGANs) for direct sinogram‐to‐image PET reconstruction. A dual approach was used: simulation experiments with Zubal phantoms, which provided a controlled and reproducible environment to test the reconstruction accuracy and robustness, and validation with real patient datasets, ensuring the method’s applicability and effectiveness in clinical settings. The primary objective was to evaluate the ability of the cGAN‐based method to enhance image quality, reduce noise, and improve reconstruction speed compared to conventional algorithms, such as maximum likelihood expectation maximization (MLEM) and total variation (TV). The methodology involved training a U‐net‐based generator and a whole‐image discriminator iteratively to reconstruct PET images with superior resolution and accuracy. Key outcome measures included bias, variance, structural similarity index (SSIM), and relative root mean square error (rRMSE), as these metrics effectively quantify image fidelity, noise levels, and structural accuracy, which are critical for evaluating the clinical reliability and precision of reconstructed PET images. The results showed that the proposed method achieved significant improvements in image clarity, noise suppression, and computational efficiency, outperforming the traditional techniques. These findings highlight the potential of cGAN‐based reconstruction in improving diagnostic accuracy and clinical workflow.

Journal of Electrical and Computer EngineeringVol. 2025(1)
Northern Technical University (IQ), Al-Furat Al-Awsat Technical University (IQ)
Openalex Percentile: Top 11%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.