Indoor air quality in naturally ventilated classrooms and offices in Ireland

• Reduced ventilation patterns associated with prioritising thermal comfort. • Indoor PM 2.5 exceeded guidelines on 48 % of monitored days, correlated with outdoor PM 2.5 . • Distinct temporal variations in pollution levels, particularly PM 2.5 , CO 2 and TVOCs. • Intra-building variation patterns occasionally exceeded inter-building differences. • Measured higher formaldehyde concentrations compared to previous studies. Indoor air quality in naturally ventilated offices and schools has significant implications for occupant health, well-being, and performance. This study conducted comprehensive multi-zone IAQ monitoring across 17 buildings - 8 office buildings, and 9 schools (51 environments in total) in Ireland, examining zonal and temporal variations in key parameters. Real-time monitoring of PM 2.5 , CO 2 , temperature, relative humidity, and total volatile organic compounds was complemented by passive sampling of formaldehyde, BTEX, pinene, limonene, and NO 2 . Results revealed distinct patterns in offices and schools, with CO 2 concentrations in classrooms (median 1319 ppm) significantly exceeding office levels (median 714 ppm) during occupied periods. PM 2.5 and NO 2 concentrations were dependent on outdoor concentrations. PM 2.5 showed a strong correlation with outdoor levels ( r = 0.75) and 48 % of monitored days exceeded WHO 24-hour guidelines. Median formaldehyde concentrations of 19 μg/m 3 and 20 μg/m 3 in offices and classrooms respectively were notably higher than previous studies. In contrast, limonene was detected in 76 % of schools compared to only 16 % of offices. Substantial variation was observed both between and within buildings, with some pollutants showing greater intra-building than inter-building variability. Both indoor and outdoor temperatures emerged as key factors influencing ventilation behaviour, particularly in classrooms where lower temperatures were associated with higher CO 2 concentrations. The results highlight the ongoing challenges in balancing thermal comfort, ventilation and IAQ. Overall, these findings offer insights to guide policy development in naturally ventilated offices and schools, enabling evidence-based policy strategies to mitigate indoor air pollution exposure and enhance occupant health and well-being.

Authors

Publication Details

Journal
Building and Environment
Published
2025-04-17
DOI
https://doi.org/10.1016/j.buildenv.2025.113023
Citations
3
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
3.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor air quality in naturally ventilated classrooms and offices in Ireland

James A. McGrath, Adam Collison, Miriam Byrne
3 citations
Building and Environment
Air Quality and Health Impacts
3.60
article

Indoor air quality in naturally ventilated classrooms and offices in Ireland

James A. McGrath, Adam Collison, Miriam Byrne
article en
3 citations

Abstract

• Reduced ventilation patterns associated with prioritising thermal comfort. • Indoor PM 2.5 exceeded guidelines on 48 % of monitored days, correlated with outdoor PM 2.5 . • Distinct temporal variations in pollution levels, particularly PM 2.5 , CO 2 and TVOCs. • Intra-building variation patterns occasionally exceeded inter-building differences. • Measured higher formaldehyde concentrations compared to previous studies. Indoor air quality in naturally ventilated offices and schools has significant implications for occupant health, well-being, and performance. This study conducted comprehensive multi-zone IAQ monitoring across 17 buildings - 8 office buildings, and 9 schools (51 environments in total) in Ireland, examining zonal and temporal variations in key parameters. Real-time monitoring of PM 2.5 , CO 2 , temperature, relative humidity, and total volatile organic compounds was complemented by passive sampling of formaldehyde, BTEX, pinene, limonene, and NO 2 . Results revealed distinct patterns in offices and schools, with CO 2 concentrations in classrooms (median 1319 ppm) significantly exceeding office levels (median 714 ppm) during occupied periods. PM 2.5 and NO 2 concentrations were dependent on outdoor concentrations. PM 2.5 showed a strong correlation with outdoor levels ( r = 0.75) and 48 % of monitored days exceeded WHO 24-hour guidelines. Median formaldehyde concentrations of 19 μg/m 3 and 20 μg/m 3 in offices and classrooms respectively were notably higher than previous studies. In contrast, limonene was detected in 76 % of schools compared to only 16 % of offices. Substantial variation was observed both between and within buildings, with some pollutants showing greater intra-building than inter-building variability. Both indoor and outdoor temperatures emerged as key factors influencing ventilation behaviour, particularly in classrooms where lower temperatures were associated with higher CO 2 concentrations. The results highlight the ongoing challenges in balancing thermal comfort, ventilation and IAQ. Overall, these findings offer insights to guide policy development in naturally ventilated offices and schools, enabling evidence-based policy strategies to mitigate indoor air pollution exposure and enhance occupant health and well-being.

Building and EnvironmentVol. 279
Sustainable Energy Authority of Ireland
Openalex Percentile: Top 8%
Air Quality and Health Impacts
3.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.