An Assessment of the Stereo and Near-Infrared Camera Calibration Technique Using a Novel Real-Time Approach in the Context of Resource Efficiency

This paper provides a comparative analysis of calibration techniques applicable to stereo and near-infrared (NIR) camera systems, with a specific emphasis on the Intel RealSense SR300 alongside a standard 2-megapixel NIR camera. This study investigates the pivotal function of calibration within both stereo vision and NIR imaging applications, which are essential across various domains, including robotics, augmented reality, and low-light imaging. For stereo systems, we scrutinise the conventional method involving a 9 × 6 chessboard pattern utilised to ascertain the intrinsic and extrinsic camera parameters. The proposed methodology consists of three main steps: (1) real-time calibration error classification for stereo cameras, (2) NIR-specific calibration techniques, and (3) a comprehensive evaluation framework. This research introduces a novel real-time evaluation methodology that classifies calibration errors predicated on the pixel offsets between corresponding points in the left and right images. Conversely, NIR camera calibration techniques are modified to address the distinctive properties of near-infrared light. We deliberate on the difficulties encountered in devising NIR–visible calibration patterns and the imperative to consider the spectral response and temperature sensitivity within the calibration procedure. The paper also puts forth an innovative calibration assessment application that is relevant to both systems. Stereo cameras evaluate the corner detection accuracy in real time across multiple image pairs, whereas NIR cameras concentrate on assessing the distortion correction and intrinsic parameter accuracy under varying lighting conditions. Our experiments validate the necessity of routine calibration assessment, as environmental factors may compromise the calibration quality over time. We conclude by underscoring the disparities in the calibration requirements between stereo and NIR systems, thereby emphasising the need for specialised approaches tailored to each domain to guarantee an optimal performance in their respective applications.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-04-15
DOI
https://doi.org/10.3390/pr13041198
Primary Topic
Advanced Vision and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Assessment of the Stereo and Near-Infrared Camera Calibration Technique Using a Novel Real-Time Approach in the Context of Resource Efficiency

Larisa Ivaşcu, Mihail Gaianu, Vlad-Florin Vinatu
Processes
Advanced Vision and Imaging
article

An Assessment of the Stereo and Near-Infrared Camera Calibration Technique Using a Novel Real-Time Approach in the Context of Resource Efficiency

Larisa Ivaşcu, Mihail Gaianu, Vlad-Florin Vinatu
article en

Abstract

This paper provides a comparative analysis of calibration techniques applicable to stereo and near-infrared (NIR) camera systems, with a specific emphasis on the Intel RealSense SR300 alongside a standard 2-megapixel NIR camera. This study investigates the pivotal function of calibration within both stereo vision and NIR imaging applications, which are essential across various domains, including robotics, augmented reality, and low-light imaging. For stereo systems, we scrutinise the conventional method involving a 9 × 6 chessboard pattern utilised to ascertain the intrinsic and extrinsic camera parameters. The proposed methodology consists of three main steps: (1) real-time calibration error classification for stereo cameras, (2) NIR-specific calibration techniques, and (3) a comprehensive evaluation framework. This research introduces a novel real-time evaluation methodology that classifies calibration errors predicated on the pixel offsets between corresponding points in the left and right images. Conversely, NIR camera calibration techniques are modified to address the distinctive properties of near-infrared light. We deliberate on the difficulties encountered in devising NIR–visible calibration patterns and the imperative to consider the spectral response and temperature sensitivity within the calibration procedure. The paper also puts forth an innovative calibration assessment application that is relevant to both systems. Stereo cameras evaluate the corner detection accuracy in real time across multiple image pairs, whereas NIR cameras concentrate on assessing the distortion correction and intrinsic parameter accuracy under varying lighting conditions. Our experiments validate the necessity of routine calibration assessment, as environmental factors may compromise the calibration quality over time. We conclude by underscoring the disparities in the calibration requirements between stereo and NIR systems, thereby emphasising the need for specialised approaches tailored to each domain to guarantee an optimal performance in their respective applications.

ProcessesVol. 13(4)
West University of Timişoara (RO), Polytechnic University of Timişoara (RO), Siemens (Romania) (RO)
Openalex Percentile: Top 94%
Advanced Vision and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.