Performance Study of Anticoagulants and Animal Blood for Establishment of In Vitro Blood Circulation Loop System

Background: In vitro blood circulation loop systems are utilized to assess the hemocompatibility and performance of medical devices that come into contact with blood, in accordance with the international standards ASTM F1830 and ASTM F1841. However, a method for evaluating the specific type of anticoagulant and the blood characteristics of each animal species is necessary to ensure consistent and reliable results. Methods: Blood was collected from healthy rabbits, pigs, rhesus monkeys, and cynomolgus monkeys to evaluate whole blood preserved in anticoagulants (ACD-A, CPDA-1, and heparin). For each sample, red blood cells were monitored over time, and their morphological characteristics were documented. Results: The morphological grade of erythrocytes gradually decreased over time. Significant differences were observed based on the type of anticoagulant used in the experiment, and variations were noted among different animal species. Conclusions: The hemocompatibility of in vitro blood circulation loop systems may vary depending on the animal species. Observing erythrocyte morphology can serve as a control measure to ensure reproducible results.

Authors

Institutions

Publication Details

Journal
LabMed
Published
2025-04-16
DOI
https://doi.org/10.3390/labmed2020007
Citations
1
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Study of Anticoagulants and Animal Blood for Establishment of In Vitro Blood Circulation Loop System

Jeong Hwa Kim, Tae‐Won Kim
1 citations
LabMed
Fuel Cells and Related Materials
0.73
article

Performance Study of Anticoagulants and Animal Blood for Establishment of In Vitro Blood Circulation Loop System

Jeong Hwa Kim, Tae‐Won Kim
article en
1 citations

Abstract

Background: In vitro blood circulation loop systems are utilized to assess the hemocompatibility and performance of medical devices that come into contact with blood, in accordance with the international standards ASTM F1830 and ASTM F1841. However, a method for evaluating the specific type of anticoagulant and the blood characteristics of each animal species is necessary to ensure consistent and reliable results. Methods: Blood was collected from healthy rabbits, pigs, rhesus monkeys, and cynomolgus monkeys to evaluate whole blood preserved in anticoagulants (ACD-A, CPDA-1, and heparin). For each sample, red blood cells were monitored over time, and their morphological characteristics were documented. Results: The morphological grade of erythrocytes gradually decreased over time. Significant differences were observed based on the type of anticoagulant used in the experiment, and variations were noted among different animal species. Conclusions: The hemocompatibility of in vitro blood circulation loop systems may vary depending on the animal species. Observing erythrocyte morphology can serve as a control measure to ensure reproducible results.

LabMedVol. 2(2)
Korea Testing Certification (KR)
Ministry of Food and Drug Safety, Korea Research Institute of Bioscience and Biotechnology
Openalex Percentile: Top 29%
Fuel Cells and Related Materials
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Study of Anticoagulants and Animal Blood for Establishment of In Vitro Blood Circulation Loop System — Jeong Hwa Kim, Tae‐Won Kim · LabMed (2025) | TGRS Research Map | TGRS