Design of cryogenic balance temperature control system based on MCGS and PLC and analysis of its influence relationship

Abstract To address the issue of slow temperature adjustment in cryogenic balance, which severely affects the efficiency of wind tunnel tests, this study investigates the temperature control system for cryogenic balance. Considering the wide temperature range and deep cooling requirements of cryogenic wind tunnels, a comprehensive design of the temperature cryogenic was developed. Based on MCGS and PLC, the first domestically developed cryogenic balance temperature control system was implemented. After installation, equipment testing and wind tunnel experiments were conducted. The experimental results indicate that the newly developed system achieves stable temperature control from room temperature to 110 K, which operates reliably, conserves energy, and significantly improves the economic efficiency of cryogenic wind tunnel tests. Furthermore, an analysis of the relationships between balance temperature range, system pressure, and wind tunnel temperature on the system’s thermal performance during tests provides valuable insights for precise control in future applications.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-04-01
DOI
https://doi.org/10.1088/1742-6596/2993/1/012024
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of cryogenic balance temperature control system based on MCGS and PLC and analysis of its influence relationship

Guangwei Xiang, Aiwei Yang, Dawei Liu, Gun Li
1 links
Journal of Physics Conference Series
Refrigeration and Air Conditioning Technologies
article

Design of cryogenic balance temperature control system based on MCGS and PLC and analysis of its influence relationship

Guangwei Xiang, Aiwei Yang, Dawei Liu, Gun Li
article en

Abstract

Abstract To address the issue of slow temperature adjustment in cryogenic balance, which severely affects the efficiency of wind tunnel tests, this study investigates the temperature control system for cryogenic balance. Considering the wide temperature range and deep cooling requirements of cryogenic wind tunnels, a comprehensive design of the temperature cryogenic was developed. Based on MCGS and PLC, the first domestically developed cryogenic balance temperature control system was implemented. After installation, equipment testing and wind tunnel experiments were conducted. The experimental results indicate that the newly developed system achieves stable temperature control from room temperature to 110 K, which operates reliably, conserves energy, and significantly improves the economic efficiency of cryogenic wind tunnel tests. Furthermore, an analysis of the relationships between balance temperature range, system pressure, and wind tunnel temperature on the system’s thermal performance during tests provides valuable insights for precise control in future applications.

Journal of Physics Conference SeriesVol. 2993(1)
University of Electronic Science and Technology of China (CN), China Aerodynamics Research and Development Center (CN)
Openalex Percentile: Top 93%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design of cryogenic balance temperature control system based on MCGS and PLC and analysis of its influence relationship — Guangwei Xiang, Aiwei Yang, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS