The Optimization of a T-Cell Resonator: Towards Highly Sensitive Photoacoustic Spectroscopy for Noninvasive Blood Glucose Detection

Noninvasive blood glucose monitoring is crucial for diabetes management, and photoacoustic spectroscopy (PAS) offers a promising solution by detecting glucose levels through human skin. However, weak acoustic signals in PAS systems require optimized resonator designs for enhanced detection sensitivity. Designing such resonators physically is complex, requiring the precise identification of critical parameters before practical implementation. This study focused on optimizing a T-shaped photoacoustic resonator using finite element modeling in a COMSOL Multiphysics environment. By systematically varying the geometric design parameters of the T-cell resonator, a maximum increase in the pressure amplitude of 12.76 times with a quality factor (Q-factor) of 47.5 was achieved compared to the previously designed reference acoustic resonator. This study took a significant step forward by identifying key geometric parameters that influence resonator performance, paving the way for more sensitive and reliable noninvasive glucose monitoring systems.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-04-16
DOI
https://doi.org/10.3390/bios15040254
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Optimization of a T-Cell Resonator: Towards Highly Sensitive Photoacoustic Spectroscopy for Noninvasive Blood Glucose Detection

Md Rejvi Kaysir, Shazzad Rassel, Dayan Ban, Thasin Mohammad Zaman
Biosensors
Photoacoustic and Ultrasonic Imaging
article

The Optimization of a T-Cell Resonator: Towards Highly Sensitive Photoacoustic Spectroscopy for Noninvasive Blood Glucose Detection

Md Rejvi Kaysir, Shazzad Rassel, Dayan Ban, Thasin Mohammad Zaman
article en

Abstract

Noninvasive blood glucose monitoring is crucial for diabetes management, and photoacoustic spectroscopy (PAS) offers a promising solution by detecting glucose levels through human skin. However, weak acoustic signals in PAS systems require optimized resonator designs for enhanced detection sensitivity. Designing such resonators physically is complex, requiring the precise identification of critical parameters before practical implementation. This study focused on optimizing a T-shaped photoacoustic resonator using finite element modeling in a COMSOL Multiphysics environment. By systematically varying the geometric design parameters of the T-cell resonator, a maximum increase in the pressure amplitude of 12.76 times with a quality factor (Q-factor) of 47.5 was achieved compared to the previously designed reference acoustic resonator. This study took a significant step forward by identifying key geometric parameters that influence resonator performance, paving the way for more sensitive and reliable noninvasive glucose monitoring systems.

BiosensorsVol. 15(4)
Khulna University of Engineering and Technology (BD), University of Waterloo (CA), Tennessee State University (US)
Good health and well-being
Openalex Percentile: Top 93%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Optimization of a T-Cell Resonator: Towards Highly Sensitive Photoacoustic Spectroscopy for Noninvasive Blood Glucose Detection — Md Rejvi Kaysir, Shazzad Rassel, et al. · Biosensors (2025) | TGRS Research Map | TGRS