Dynamic dilution calibration method for non-radioactive methyl iodine tester

Abstract The non-radioactive methyl iodine tester is mainly used to measure the methyl iodine concentration in the ventilation system of nuclear power plants. In order to ensure the accuracy and reliability of the measurement data, the measurement instrument must be calibrated regularly. In this paper, a calibration method for a non-radioactive methyl iodine tester is proposed based on the dynamic dilution method. Calibration items such as value error, measurement repeatability, stability, linearity, and relative deviation of integral concentration are presented. Their reference indexes are shown. The rationality of the calibration work of a non-radioactive methyl iodine tester by dynamic dilution method is verified.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-04-01
DOI
https://doi.org/10.1088/1742-6596/2990/1/012015
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic dilution calibration method for non-radioactive methyl iodine tester

Yao Tian, Yumeng Liu, Zhaojie Li, Wei Chang et al.
Journal of Physics Conference Series
Advanced Sensor Technologies Research
article

Dynamic dilution calibration method for non-radioactive methyl iodine tester

Yao Tian, Yumeng Liu, Zhaojie Li, Wei Chang, Yunfei Zhang, Shuai Yang, Tong He, Sijun Fan, K. Tian, Weiye Yin
article en

Abstract

Abstract The non-radioactive methyl iodine tester is mainly used to measure the methyl iodine concentration in the ventilation system of nuclear power plants. In order to ensure the accuracy and reliability of the measurement data, the measurement instrument must be calibrated regularly. In this paper, a calibration method for a non-radioactive methyl iodine tester is proposed based on the dynamic dilution method. Calibration items such as value error, measurement repeatability, stability, linearity, and relative deviation of integral concentration are presented. Their reference indexes are shown. The rationality of the calibration work of a non-radioactive methyl iodine tester by dynamic dilution method is verified.

Journal of Physics Conference SeriesVol. 2990(1)
China General Nuclear Power Corporation (China) (CN), Suzhou Research Institute (CN)
Openalex Percentile: Top 93%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dynamic dilution calibration method for non-radioactive methyl iodine tester — Yao Tian, Yumeng Liu, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS