Research on the influencing factors of dynamic parameter detection technology for shock tube

Abstract As a device for simulating shock waves, shock tubes can generate a type of step pressure signal and are the excitation source in the dynamic parameter detection technology of shock tubes. Based on actual measurement conditions, the influence of different installation methods and temperature coupling conditions on dynamic parameter measurement was quantitatively analyzed. The measurement results show that the influence of convex installation on resonant frequency parameters is increased by 1.47%. When the influence of concave installation on resonant frequency parameters is reduced by 1.89%, the step rise time is reduced by 1.997 μs, about 39.12%. When the temperature is lower, the resonant frequency point is bigger, revealing that the wider the frequency band is, the better the performance is. The step rise time does not change much at 80℃ high temperature, and the measurement value appears to be the maximum error, which is 4.3%.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-04-01
DOI
https://doi.org/10.1088/1742-6596/2990/1/012010
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the influencing factors of dynamic parameter detection technology for shock tube

Ben Li, Kun Zhang, Liangliang Zhang, Yu Fu
3 links
Journal of Physics Conference Series
Advanced Measurement and Detection Methods
article

Research on the influencing factors of dynamic parameter detection technology for shock tube

Ben Li, Kun Zhang, Liangliang Zhang, Yu Fu
article en

Abstract

Abstract As a device for simulating shock waves, shock tubes can generate a type of step pressure signal and are the excitation source in the dynamic parameter detection technology of shock tubes. Based on actual measurement conditions, the influence of different installation methods and temperature coupling conditions on dynamic parameter measurement was quantitatively analyzed. The measurement results show that the influence of convex installation on resonant frequency parameters is increased by 1.47%. When the influence of concave installation on resonant frequency parameters is reduced by 1.89%, the step rise time is reduced by 1.997 μs, about 39.12%. When the temperature is lower, the resonant frequency point is bigger, revealing that the wider the frequency band is, the better the performance is. The step rise time does not change much at 80℃ high temperature, and the measurement value appears to be the maximum error, which is 4.3%.

Journal of Physics Conference SeriesVol. 2990(1)
China North Industries Group Corporation (China) (CN)
Openalex Percentile: Top 94%
Advanced Measurement and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.