Improvements in the Deflection Angle Allowed for Pipe, with an Operating Temperature below 50 °C, Coated with non-VOC Liquid Resin, at a Lower Thickness than Recommended for High Temperature.

Abstract Currently all coat manufacturers show performances and properties of products in a datasheet, which show everyone of test and coating’s behavior under operating conditions related with the environment where it will be buried. This paper describes that client specified a coating thickness that Is below the minimun recommended by the product manufacturer in datasheet. It is crucial to note that this líquid epoxy resin (LBE) Novolac is intented for use at temperatures higher than those expected during operation and round approximately 50°C compared with the 150°C raised by the coating at 30 mils in thickness, and the bend angles applied in pipes exceed the manufacturer’s recommendation in advance (5 to 7 degree PLD), however the lined pipes passed all the test in lab as CAN/CSA Z245-20-02, PDVSA-EM-01-01/20, ISO 21809-2:2014, AWWA C 213, ASTM D-570 and ASTM D2240. The bending test rise high angles probably due to the gradual cold working process used and the good adherence of coat at less thickness with acceptable hardness (average of 23 mils compared to 30 mils used commonly). The cathodic detachment test be accelerated, 48 hours at 95°C according to the standard CAN/CSA Z245-20 to comply with delivery times. Although the temperature of the fluid to be transported in the pipeline does not exceed 50°C, there are neighboring pipelines where it will be buried whose temperature rised 70°C

Authors

Publication Details

Published
2025-04-06
DOI
https://doi.org/10.5006/c2025-00056
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvements in the Deflection Angle Allowed for Pipe, with an Operating Temperature below 50 °C, Coated with non-VOC Liquid Resin, at a Lower Thickness than Recommended for High Temperature.

Edgardo Tamaronis
Geotechnical Engineering and Underground Structures
article

Improvements in the Deflection Angle Allowed for Pipe, with an Operating Temperature below 50 °C, Coated with non-VOC Liquid Resin, at a Lower Thickness than Recommended for High Temperature.

Edgardo Tamaronis
article en

Abstract

Abstract Currently all coat manufacturers show performances and properties of products in a datasheet, which show everyone of test and coating’s behavior under operating conditions related with the environment where it will be buried. This paper describes that client specified a coating thickness that Is below the minimun recommended by the product manufacturer in datasheet. It is crucial to note that this líquid epoxy resin (LBE) Novolac is intented for use at temperatures higher than those expected during operation and round approximately 50°C compared with the 150°C raised by the coating at 30 mils in thickness, and the bend angles applied in pipes exceed the manufacturer’s recommendation in advance (5 to 7 degree PLD), however the lined pipes passed all the test in lab as CAN/CSA Z245-20-02, PDVSA-EM-01-01/20, ISO 21809-2:2014, AWWA C 213, ASTM D-570 and ASTM D2240. The bending test rise high angles probably due to the gradual cold working process used and the good adherence of coat at less thickness with acceptable hardness (average of 23 mils compared to 30 mils used commonly). The cathodic detachment test be accelerated, 48 hours at 95°C according to the standard CAN/CSA Z245-20 to comply with delivery times. Although the temperature of the fluid to be transported in the pipeline does not exceed 50°C, there are neighboring pipelines where it will be buried whose temperature rised 70°C

Openalex Percentile: Top 92%
Geotechnical Engineering and Underground Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.