Intelligent data-driven methods for enhancing distributed excitation control in electrical grid

This paper proposes a decentralized excitation control method based on synchronized estimation using asynchronous measurements from voltage/current transformers (VT/CT), addressing the challenges of decentralized excitation control caused by asynchronous updates. Due to the high cost and limited use of Phasor Measurement Units (PMUs), synchronized generator output measurements are often not feasible. The proposed method establishes a framework for decentralized excitation control that aligns with synchronized estimation in multi-machine power systems. It develops an estimation model for synchronized acquisition of excitation control feedback inputs, even under asynchronous sampling conditions. Simulation results using IEEE standard test systems demonstrate that synchronized estimated values offer a more accurate representation of the system’s status compared to asynchronous measurements, with better compatibility with the network structure. The findings show that decentralized excitation control based on synchronized estimation significantly enhances power system stability compared to traditional control methods that rely on asynchronous feedback.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-04-16
DOI
https://doi.org/10.1049/icp.2025.1157
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intelligent data-driven methods for enhancing distributed excitation control in electrical grid

Muhammad Zain Yousaf, Muhammad Imran, Fareed Ahmad, Ayesha Riaz et al.
IET conference proceedings.
Power Systems and Technologies
article

Intelligent data-driven methods for enhancing distributed excitation control in electrical grid

Muhammad Zain Yousaf, Muhammad Imran, Fareed Ahmad, Ayesha Riaz, Imran Khan, Hafiz Ghulam Murtza Qamar, A. Mohammed Ashraf
article en

Abstract

This paper proposes a decentralized excitation control method based on synchronized estimation using asynchronous measurements from voltage/current transformers (VT/CT), addressing the challenges of decentralized excitation control caused by asynchronous updates. Due to the high cost and limited use of Phasor Measurement Units (PMUs), synchronized generator output measurements are often not feasible. The proposed method establishes a framework for decentralized excitation control that aligns with synchronized estimation in multi-machine power systems. It develops an estimation model for synchronized acquisition of excitation control feedback inputs, even under asynchronous sampling conditions. Simulation results using IEEE standard test systems demonstrate that synchronized estimated values offer a more accurate representation of the system’s status compared to asynchronous measurements, with better compatibility with the network structure. The findings show that decentralized excitation control based on synchronized estimation significantly enhances power system stability compared to traditional control methods that rely on asynchronous feedback.

IET conference proceedings.Vol. 2025(3)
University of Sargodha (PK), Yanshan University (CN), Zhejiang University (CN)
Affordable and clean energy
Openalex Percentile: Top 94%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.