CO2 Transport - Corrosion of Carbon Steel Exposed to Inhibited Water Pools Present after Commissioning

Abstract Water pools might remain in CO2 transport pipelines after installation and commissioning or be present due to accidental ingress of water. The pipelines are normally made of carbon steel and the corrosion rate of the exposed steel will depend on a number of parameters including CO2 partial pressure (pCO2), flow velocity, temperature, water volume to steel surface ratio (Vaq/S ratio), water composition, presence of impurities (SOx, NOx, H2S, O2) in the CO2 stream, and corrosion and hydrate inhibiting chemicals. A corrosion inhibitor testing program was performed under simulated commissioning and start-up conditions. Two inhibitors were tested. The experiments were performed in static autoclaves and transparent test cells at CO2 pressures up to 100 MPa. Impurities (SOx, NOx, H2S, O2) and reaction products (H2SO4, HNO3) were injected/present at various concentrations.

Authors

Institutions

Publication Details

Published
2025-04-06
DOI
https://doi.org/10.5006/c2025-00407
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CO2 Transport - Corrosion of Carbon Steel Exposed to Inhibited Water Pools Present after Commissioning

Roberto Morana, William Durnie, Charlotte Vie, Arne Dugstad et al.
Concrete Corrosion and Durability
article

CO2 Transport - Corrosion of Carbon Steel Exposed to Inhibited Water Pools Present after Commissioning

Roberto Morana, William Durnie, Charlotte Vie, Arne Dugstad, Bjørn H. Morland, Louis Doyle
article en

Abstract

Abstract Water pools might remain in CO2 transport pipelines after installation and commissioning or be present due to accidental ingress of water. The pipelines are normally made of carbon steel and the corrosion rate of the exposed steel will depend on a number of parameters including CO2 partial pressure (pCO2), flow velocity, temperature, water volume to steel surface ratio (Vaq/S ratio), water composition, presence of impurities (SOx, NOx, H2S, O2) in the CO2 stream, and corrosion and hydrate inhibiting chemicals. A corrosion inhibitor testing program was performed under simulated commissioning and start-up conditions. Two inhibitors were tested. The experiments were performed in static autoclaves and transparent test cells at CO2 pressures up to 100 MPa. Impurities (SOx, NOx, H2S, O2) and reaction products (H2SO4, HNO3) were injected/present at various concentrations.

BP (United Kingdom) (GB)
Openalex Percentile: Top 92%
Concrete Corrosion and Durability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CO2 Transport - Corrosion of Carbon Steel Exposed to Inhibited Water Pools Present after Commissioning — Roberto Morana, William Durnie, et al. · (2025) | TGRS Research Map | TGRS