Case Study: Identifying an Intermittently Shorted Casing During Indirect Inspections

Abstract Pipeline casings have been used to protect pipelines from additional stress when pipelines are placed under roads, railroads, and other reasons for decades. The interactions between pipelines and casings have thoroughly been discussed in the pipeline integrity industry. The risks associated with metallic shorts and electrolytic couples are well documented and it is commonly understood that a metallically shorted pipeline with a metallic casing will depress cathodic protection (CP) potentials, but what happens when this local depression is not seen on subsequent cathodic protection surveys? This paper will discuss a case study where a transmission pipeline, that parallels and is electrically continuous with another transmission pipeline, was surveyed via an interrupted close interval survey (CIS) and followed by a depolarized close interval survey as well as additional interrupted close interval surveys that had varying results at a cased crossing. This case study explains the test methods and documents reviewed that went into determining the cause of this occurrence.

Authors

Publication Details

Published
2025-04-06
DOI
https://doi.org/10.5006/c2025-00525
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case Study: Identifying an Intermittently Shorted Casing During Indirect Inspections

Steven Wenzel, Will Menard
Non-Destructive Testing Techniques
article

Case Study: Identifying an Intermittently Shorted Casing During Indirect Inspections

Steven Wenzel, Will Menard
article en

Abstract

Abstract Pipeline casings have been used to protect pipelines from additional stress when pipelines are placed under roads, railroads, and other reasons for decades. The interactions between pipelines and casings have thoroughly been discussed in the pipeline integrity industry. The risks associated with metallic shorts and electrolytic couples are well documented and it is commonly understood that a metallically shorted pipeline with a metallic casing will depress cathodic protection (CP) potentials, but what happens when this local depression is not seen on subsequent cathodic protection surveys? This paper will discuss a case study where a transmission pipeline, that parallels and is electrically continuous with another transmission pipeline, was surveyed via an interrupted close interval survey (CIS) and followed by a depolarized close interval survey as well as additional interrupted close interval surveys that had varying results at a cased crossing. This case study explains the test methods and documents reviewed that went into determining the cause of this occurrence.

Openalex Percentile: Top 93%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Case Study: Identifying an Intermittently Shorted Casing During Indirect Inspections — Steven Wenzel, Will Menard · (2025) | TGRS Research Map | TGRS