Evaluating, Quantifying, and Reducing the Capacitive Effect of an Existing AC Mitigation System Utilizing Advanced Modeling Techniques

Abstract An evaluation of the capacitive effect of solid-state decouplers (SSDs) was completed on a transmission pipeline in the Midwest region of the United States. The existing alternating current (AC) mitigation system was comprised of 95 SSDs and approximately 33,000 ft (10058.4 m) of electrode installed along 14 mi (22.5308 km) of multi-pipeline right-of-way (ROW). The cumulative capacitive effect of the existing system required any indirect survey to be performed on a severely elongated interruption cycle to obtain accurate IR-free potentials, resulting in a significant increase in survey cost and reduced efficiency. Computer modeling was used to better understand the effect of multiple variables on the system’s capacitance. The results were analyzed using a multiple regression model; existing assets and survey data were reviewed, and opportunities were identified to reduce the number of decoupling devices required to adequately protect the system. The remaining devices were ranked for replacement to a newer model of SSD that masks its capacitive effect. This paper will discuss the approach to the study, results, and future work to be completed.

Authors

Publication Details

Published
2025-04-06
DOI
https://doi.org/10.5006/c2025-00076
Primary Topic
Reliability and Maintenance Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating, Quantifying, and Reducing the Capacitive Effect of an Existing AC Mitigation System Utilizing Advanced Modeling Techniques

S.W. Wenzel, Bradley O’Hagan
Reliability and Maintenance Optimization
article

Evaluating, Quantifying, and Reducing the Capacitive Effect of an Existing AC Mitigation System Utilizing Advanced Modeling Techniques

S.W. Wenzel, Bradley O’Hagan
article en

Abstract

Abstract An evaluation of the capacitive effect of solid-state decouplers (SSDs) was completed on a transmission pipeline in the Midwest region of the United States. The existing alternating current (AC) mitigation system was comprised of 95 SSDs and approximately 33,000 ft (10058.4 m) of electrode installed along 14 mi (22.5308 km) of multi-pipeline right-of-way (ROW). The cumulative capacitive effect of the existing system required any indirect survey to be performed on a severely elongated interruption cycle to obtain accurate IR-free potentials, resulting in a significant increase in survey cost and reduced efficiency. Computer modeling was used to better understand the effect of multiple variables on the system’s capacitance. The results were analyzed using a multiple regression model; existing assets and survey data were reviewed, and opportunities were identified to reduce the number of decoupling devices required to adequately protect the system. The remaining devices were ranked for replacement to a newer model of SSD that masks its capacitive effect. This paper will discuss the approach to the study, results, and future work to be completed.

Openalex Percentile: Top 92%
Reliability and Maintenance Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating, Quantifying, and Reducing the Capacitive Effect of an Existing AC Mitigation System Utilizing Advanced Modeling Techniques — S.W. Wenzel, Bradley O’Hagan · (2025) | TGRS Research Map | TGRS