A Case Study of External Cracking in Steam Piping under Mineral Wool Insulation

In recent years, cracking has been observed in carbon steel piping systems operating at temperatures above 70°C. These systems, equipped with mineral wool insulation and aluminum cladding, experienced cracking and failures under normal operating pressures and temperatures. Leachates from wet mineral wool insulation are suspected of causing external stress corrosion cracking (SCC) in these scenarios. A failure in a carbon steel steam condensate return pipe occurred at 50 PSI(g) and 330°F. Gaps in the insulation cladding allowed moisture to accumulate, which led to external stress corrosion cracking, particularly at the underside of the pipe where moisture collects. Material samples taken from the failed pipe showed intergranular cracking and grain elongation at the base of the cracks. This paper summarizes the findings of the investigation into the steam condensate piping failure, aiming to raise industry awareness and promote the safe operation of similar systems.

Authors

Institutions

Publication Details

Published
2025-04-06
DOI
https://doi.org/10.5006/c2025-00311
Citations
1
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Case Study of External Cracking in Steam Piping under Mineral Wool Insulation

Yashar Behnamian, Simon Yuen, Neetesh Soni, Aaron Mcdonald et al.
1 citations
Non-Destructive Testing Techniques
0.71
article

A Case Study of External Cracking in Steam Piping under Mineral Wool Insulation

Yashar Behnamian, Simon Yuen, Neetesh Soni, Aaron Mcdonald, Nirajkumar Mehta, Duane Serate, Sudeep Bohra, Haixia Guo
article en
1 citations

Abstract

In recent years, cracking has been observed in carbon steel piping systems operating at temperatures above 70°C. These systems, equipped with mineral wool insulation and aluminum cladding, experienced cracking and failures under normal operating pressures and temperatures. Leachates from wet mineral wool insulation are suspected of causing external stress corrosion cracking (SCC) in these scenarios. A failure in a carbon steel steam condensate return pipe occurred at 50 PSI(g) and 330°F. Gaps in the insulation cladding allowed moisture to accumulate, which led to external stress corrosion cracking, particularly at the underside of the pipe where moisture collects. Material samples taken from the failed pipe showed intergranular cracking and grain elongation at the base of the cracks. This paper summarizes the findings of the investigation into the steam condensate piping failure, aiming to raise industry awareness and promote the safe operation of similar systems.

Suncor Energy (Canada) (CA)
Openalex Percentile: Top 34%
Non-Destructive Testing Techniques
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Case Study of External Cracking in Steam Piping under Mineral Wool Insulation — Yashar Behnamian, Simon Yuen, et al. · (2025) | TGRS Research Map | TGRS