Cardiac MRI Segmentation of Ventricular Structures and Myocardium Using U-Net Variants

Accurate segmentation of the ventricular structures and myocardium from Cardiac Magnetic Resonance (CMR) images is essential to diagnose and manage cardiovascular diseases. This study systematically evaluates the performance of five U-Net variants in cardiac MRI segmentation using the Automated Cardiac Diagnosis Challenge (ACDC) dataset and a hybrid loss function combining Cross-Entropy and dice losses. Among the variants, the Feature Pyramid U-Net achieved the best performance, with Dice coefficients of 0.9388 (Left Ventricle), 0.8759 (Right Ventricle), and 0.8426 (Myocardium), showcasing its superior ability to capture multi-scale features and segment complex anatomical structures. The comprehensive and standardized evaluation conducted in this study provides valuable insights into the strengths and limitations of these architectures for cardiac segmentation.

Authors

Institutions

Publication Details

Published
2025-02-19
DOI
https://doi.org/10.1109/icarc64760.2025.10963166
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac MRI Segmentation of Ventricular Structures and Myocardium Using U-Net Variants

Chinthalanka B. Wijesinghe, Dulani Meedeniya, Pratheepan Yogarajah
1 citations
Advanced X-ray and CT Imaging
0.67
article

Cardiac MRI Segmentation of Ventricular Structures and Myocardium Using U-Net Variants

Chinthalanka B. Wijesinghe, Dulani Meedeniya, Pratheepan Yogarajah
article en
1 citations

Abstract

Accurate segmentation of the ventricular structures and myocardium from Cardiac Magnetic Resonance (CMR) images is essential to diagnose and manage cardiovascular diseases. This study systematically evaluates the performance of five U-Net variants in cardiac MRI segmentation using the Automated Cardiac Diagnosis Challenge (ACDC) dataset and a hybrid loss function combining Cross-Entropy and dice losses. Among the variants, the Feature Pyramid U-Net achieved the best performance, with Dice coefficients of 0.9388 (Left Ventricle), 0.8759 (Right Ventricle), and 0.8426 (Myocardium), showcasing its superior ability to capture multi-scale features and segment complex anatomical structures. The comprehensive and standardized evaluation conducted in this study provides valuable insights into the strengths and limitations of these architectures for cardiac segmentation.

University of Ulster (GB), University of Moratuwa (LK)
Zero hunger
Openalex Percentile: Top 33%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Cardiac MRI Segmentation of Ventricular Structures and Myocardium Using U-Net Variants — Chinthalanka B. Wijesinghe, Dulani Meedeniya, et al. · (2025) | TGRS Research Map | TGRS