Combining Deep Data-Driven and Physics-Inspired Learning for Shear Wave Speed Estimation in Ultrasound Elastography

The shear wave elastography (SWE) provides quantitative markers for tissue characterization by measuring the shear wave speed (SWS), which reflects tissue stiffness. SWE uses an acoustic radiation force pulse sequence to generate shear waves that propagate laterally through tissue with transient displacements. These waves travel perpendicular to the applied force, and their displacements are tracked using high-frame-rate ultrasound. Estimating the SWS map involves two main steps: speckle tracking and SWS estimation. Speckle tracking calculates particle velocity by measuring RF/IQ data displacement between adjacent firings, while SWS estimation methods typically compare particle velocity profiles of samples that are laterally a few millimeters apart. Deep learning (DL) methods have gained attention for SWS estimation, often relying on supervised training using simulated data. However, these methods may struggle with real-world data, which can differ significantly from the simulated training data, potentially leading to artifacts in the estimated SWS map. To address this challenge, we propose a physics-inspired learning approach that utilizes real data without known SWS values. Our method employs an adaptive unsupervised loss function, allowing the network to train with the real noisy data to minimize the artifacts and improve the robustness. We validate our approach using experimental phantom data and in vivo liver data from two human subjects, demonstrating enhanced accuracy and reliability in SWS estimation compared with conventional and supervised methods. This hybrid approach leverages the strengths of both data-driven and physics-inspired learning, offering a promising solution for more accurate and robust SWS mapping in clinical applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Published
2025-04-16
DOI
https://doi.org/10.1109/tuffc.2025.3561599
Citations
2
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining Deep Data-Driven and Physics-Inspired Learning for Shear Wave Speed Estimation in Ultrasound Elastography

Theodore T. Pierce, Mike Washburn, Scott Schoen, Peng Guo et al.
2 citations
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
Ultrasound Imaging and Elastography
2.72
article

Combining Deep Data-Driven and Physics-Inspired Learning for Shear Wave Speed Estimation in Ultrasound Elastography

Theodore T. Pierce, Mike Washburn, Scott Schoen, Peng Guo, Kai E. Thomenius, Ali K. Z. Tehrani, Anthony E. Samir, Hassan Rivaz, Yuyang Gu, Rimon Tadross, Ion Candel, Michael Wang
article en
2 citations

Abstract

The shear wave elastography (SWE) provides quantitative markers for tissue characterization by measuring the shear wave speed (SWS), which reflects tissue stiffness. SWE uses an acoustic radiation force pulse sequence to generate shear waves that propagate laterally through tissue with transient displacements. These waves travel perpendicular to the applied force, and their displacements are tracked using high-frame-rate ultrasound. Estimating the SWS map involves two main steps: speckle tracking and SWS estimation. Speckle tracking calculates particle velocity by measuring RF/IQ data displacement between adjacent firings, while SWS estimation methods typically compare particle velocity profiles of samples that are laterally a few millimeters apart. Deep learning (DL) methods have gained attention for SWS estimation, often relying on supervised training using simulated data. However, these methods may struggle with real-world data, which can differ significantly from the simulated training data, potentially leading to artifacts in the estimated SWS map. To address this challenge, we propose a physics-inspired learning approach that utilizes real data without known SWS values. Our method employs an adaptive unsupervised loss function, allowing the network to train with the real noisy data to minimize the artifacts and improve the robustness. We validate our approach using experimental phantom data and in vivo liver data from two human subjects, demonstrating enhanced accuracy and reliability in SWS estimation compared with conventional and supervised methods. This hybrid approach leverages the strengths of both data-driven and physics-inspired learning, offering a promising solution for more accurate and robust SWS mapping in clinical applications.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlVol. 72(6)
Binghamton University (US), Harvard University (US), Massachusetts General Hospital (US), Concordia University (CA)
GE Healthcare
Openalex Percentile: Top 11%
Ultrasound Imaging and Elastography
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.