Lightweight Probe Cover for Wearable Thermal Device Designed Through Topology Optimization

Core body temperature (CBT) is a useful indicator of physiological changes. Wearable CBT sensors have been developed, including those based on the heat flux method, which is noninvasive but sensitive to environmental changes. An improved method that uses a high-thermal-conductivity material to cover the probe has been recently developed. However, the probe cover increases the sensor weight. Here, we develop a lightweight probe cover that maintains high measurement accuracy. The cover shape was designed using topology optimization. The total probe weight is 15 g, which is significantly lower than that reported in our previous study and is comparable to the weight of a commercial wearable sensor (12 g). Numerical simulation demonstrates that a sensor with the proposed cover can achieve a high accuracy of 0.009 °C, exceeding the tolerance error of 0.1 °C of an electronic thermometer. A human experiment shows that the wearable CBT sensor can measure temperature with an accuracy (0.027 ± 0.016 °C) higher than the tolerance error of an electronic thermometer, although not as high as the design accuracy. The results demonstrate that the sensor has potential for practical applications.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3561285
Citations
1
Primary Topic
Laser and Thermal Forming Techniques
Type
article
Field-Weighted Citation Impact
1.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightweight Probe Cover for Wearable Thermal Device Designed Through Topology Optimization

Yuki Hashimoto, Yoshifumi Nishida, Soto Tada
1 citations
IEEE Access
Laser and Thermal Forming Techniques
1.33
article

Lightweight Probe Cover for Wearable Thermal Device Designed Through Topology Optimization

Yuki Hashimoto, Yoshifumi Nishida, Soto Tada
article en
1 citations

Abstract

Core body temperature (CBT) is a useful indicator of physiological changes. Wearable CBT sensors have been developed, including those based on the heat flux method, which is noninvasive but sensitive to environmental changes. An improved method that uses a high-thermal-conductivity material to cover the probe has been recently developed. However, the probe cover increases the sensor weight. Here, we develop a lightweight probe cover that maintains high measurement accuracy. The cover shape was designed using topology optimization. The total probe weight is 15 g, which is significantly lower than that reported in our previous study and is comparable to the weight of a commercial wearable sensor (12 g). Numerical simulation demonstrates that a sensor with the proposed cover can achieve a high accuracy of 0.009 °C, exceeding the tolerance error of 0.1 °C of an electronic thermometer. A human experiment shows that the wearable CBT sensor can measure temperature with an accuracy (0.027 ± 0.016 °C) higher than the tolerance error of an electronic thermometer, although not as high as the design accuracy. The results demonstrate that the sensor has potential for practical applications.

IEEE AccessVol. 13
Institute of Science Tokyo (JP)
Casio Science Promotion Foundation, JKA Foundation, Japan Society for the Promotion of Science
Affordable and clean energy
Openalex Percentile: Top 24%
Laser and Thermal Forming Techniques
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.