Detection of Methyl Parathion by MoS<sub>2</sub>/rGO/GCE
In this paper, composite nanostructures are constructed successfully by combining conductive carbon-based materials with MoS.The MoS/ reduced Graphene Oxide (rGO) composite was synthesized by hydrothermal method, and its morphology, elemental composition and microstructure were characterized in detail.Then, the MoS/rGO composite material was modified on the glass carbon electrode (GCE) to construct the methyl parathion (MP) electrochemical sensor.The experimental results show that compared with a single MoS/GCE modified electrode, the MoS/rGO modified electrode exhibits significantly improved electrochemical performance.This boost can be attributed to the rGO's high electrical conductivity and its good interface combination with MoS, which work together to facilitate electron transport and enhance catalytic activity.In the electrochemical detection of MP, the MoS/rGO modified electrode shows excellent sensitivity, and its detection limit of MP reaches 11.92 ng/mL, providing an effective solution for the detection of MP with high sensitivity.Key words:molybdenum disulfidegraphene
Authors
- Chong Tan (ORCID: https://orcid.org/0000-0001-5688-4982)
- Junsheng Li (ORCID: https://orcid.org/0000-0001-9265-2951)
- Jinlong Zuo (ORCID: https://orcid.org/0000-0002-6218-3661)
- Yuan Qi (ORCID: https://orcid.org/0000-0001-9718-7593)
- Yuhong Yin
Institutions
- Harbin University of Commerce (CN)
Publication Details
- Journal
- Electrochemistry
- Published
- 2025-04-16
- DOI
- https://doi.org/10.5796/electrochemistry.25-00005
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00