A paper-based analytical device for rapid colorimetric detection of aluminium in aerosol antiperspirants

This work focuses on developing a simple and low-cost methodology for colorimetric analysis of aluminum in aerosol antiperspirants using paper-based analytical devices (PADs). The devices were manufactured by combining a layer of paper with two layers of pouch film, consisting of 35 circular zones with a diameter of 6 mm each. Subsequently, analytical parameters were optimized by capturing the colorimetric responses of the reaction between aluminium (III) and Eriochrome Cyanine R in proportions of 3 μL of Eriochrome Cyanine R in the concentration of 1.5 g L<sup>-1</sup> to 7 μL of aluminium solution. The effect of impregnating the paper with three different nanomaterials to improve the PAD response was also evaluated. With the help of a smartphone and an app capable of analyzing color generated from photos, the analytical curve was established in the concentration range from 1 to 6 mg L<sup>-1</sup>, achieving a LOD of 0.52 mg L<sup>-1</sup> and a LOQ of 1.56 mg L<sup>-1</sup>, with the modification of the paper with multi-walled carbon nanotubes. Subsequently, aluminium levels in aerosol antiperspirant brands were analyzed by evaluating different sample preparation methods. The results were compared with those obtained by performing the analyses using Microwave Plasma-Atomic Emission Spectroscopy (MP-AES), revealing statistically comparable results, and the recovery assay achieved recoveries ranging from 91.7 to 105.9%. Among the innovations brought by this work are the testing of new methods for preparing aerosol antiperspirant samples and the first application of the proposed modified PAD. There is the possibility of performing chemical analyses in environments with few resources and opening opportunities for many applications.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00229j
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A paper-based analytical device for rapid colorimetric detection of aluminium in aerosol antiperspirants

Michel Kendy Souza, L. A. Ferreira, Alexandre Fonseca, Ítalo A. Costa et al.
2 citations
Analytical Methods
Biosensors and Analytical Detection
1.35
article

A paper-based analytical device for rapid colorimetric detection of aluminium in aerosol antiperspirants

Michel Kendy Souza, L. A. Ferreira, Alexandre Fonseca, Ítalo A. Costa, C Chagas, Wendell K. T. Coltro, Gerson F. Duarte‐Junior, Leonardo G. Paterno, A. Carvalho
article en
2 citations

Abstract

This work focuses on developing a simple and low-cost methodology for colorimetric analysis of aluminum in aerosol antiperspirants using paper-based analytical devices (PADs). The devices were manufactured by combining a layer of paper with two layers of pouch film, consisting of 35 circular zones with a diameter of 6 mm each. Subsequently, analytical parameters were optimized by capturing the colorimetric responses of the reaction between aluminium (III) and Eriochrome Cyanine R in proportions of 3 μL of Eriochrome Cyanine R in the concentration of 1.5 g L<sup>-1</sup> to 7 μL of aluminium solution. The effect of impregnating the paper with three different nanomaterials to improve the PAD response was also evaluated. With the help of a smartphone and an app capable of analyzing color generated from photos, the analytical curve was established in the concentration range from 1 to 6 mg L<sup>-1</sup>, achieving a LOD of 0.52 mg L<sup>-1</sup> and a LOQ of 1.56 mg L<sup>-1</sup>, with the modification of the paper with multi-walled carbon nanotubes. Subsequently, aluminium levels in aerosol antiperspirant brands were analyzed by evaluating different sample preparation methods. The results were compared with those obtained by performing the analyses using Microwave Plasma-Atomic Emission Spectroscopy (MP-AES), revealing statistically comparable results, and the recovery assay achieved recoveries ranging from 91.7 to 105.9%. Among the innovations brought by this work are the testing of new methods for preparing aerosol antiperspirant samples and the first application of the proposed modified PAD. There is the possibility of performing chemical analyses in environments with few resources and opening opportunities for many applications.

Analytical MethodsVol. 17(19)
Universidade de Brasília (BR), Universidade Federal de Goiás (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 21%
Biosensors and Analytical Detection
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.