Tube Flow Shunt: An Innovative and Cost-Effective Approach to the Modified Bleb-Forming Filtration Technique

Aiming to lower intraocular pressure, trabeculectomy remains the gold standard procedure. This report describes a novel, cost-effective modified bleb-forming filtration technique, tFlow (tube flow shunt), utilizing sterile trimmed silicone tubes from the Ahmed Glaucoma Valve (AGV), model FP7, to construct a subconjunctival filtration pathway. Here, clinical outcomes are not reported and will be evaluated in a future study. While initial findings suggest it may provide a viable alternative to other modified bleb-forming filtration techniques involving commercial devices like PreserFlo MicroShunt, EX-PRESS Glaucoma Filtration Device, and XEN Gel Stent, further investigation is necessary. Additional patient inclusion and comparative studies with different bleb-forming filtration techniques are potential areas for future research.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-04-16
DOI
https://doi.org/10.7759/cureus.82399
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tube Flow Shunt: An Innovative and Cost-Effective Approach to the Modified Bleb-Forming Filtration Technique

Md Iftekher Iqbal
Cureus
Glaucoma and retinal disorders
article

Tube Flow Shunt: An Innovative and Cost-Effective Approach to the Modified Bleb-Forming Filtration Technique

Md Iftekher Iqbal
article en

Abstract

Aiming to lower intraocular pressure, trabeculectomy remains the gold standard procedure. This report describes a novel, cost-effective modified bleb-forming filtration technique, tFlow (tube flow shunt), utilizing sterile trimmed silicone tubes from the Ahmed Glaucoma Valve (AGV), model FP7, to construct a subconjunctival filtration pathway. Here, clinical outcomes are not reported and will be evaluated in a future study. While initial findings suggest it may provide a viable alternative to other modified bleb-forming filtration techniques involving commercial devices like PreserFlo MicroShunt, EX-PRESS Glaucoma Filtration Device, and XEN Gel Stent, further investigation is necessary. Additional patient inclusion and comparative studies with different bleb-forming filtration techniques are potential areas for future research.

CureusVol. 17(4)
Moorfields Eye Hospital NHS Foundation Trust (GB), He Eye Hospital (CN)
Openalex Percentile: Top 87%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.