Development, optimisation, and pre-validation of a gas chromatography—Ion mobility spectrometry method with preliminary twofold enrichment for the sensitive detection of N Nitrosamines in drinking water

• Sensitive and selective analysis method for nine N-nitrosamines in drinking waters. • Twofold enrichment via subsequent solid phase extraction and in-tube extraction. • Method development following US EPA guidelines. • Recoveries between 56.1 and 113.6 % for relevant N NOs in drinking water. • Method LODs and LOQs of 1.12 – 12.48 ng/L and 3.35 – 37.44 ng/L, respectively. N Nitrosamines have long been identified as a relevant contaminant in potable water due to their identification as probable human carcinogens. Thus, highly sensitive detection of these pollutants in the ultra-trace range is imperative to comply with strict regulatory specifications. To this end, many institutions rely on mass spectrometry-based analysis methods, which have the disadvantage of being cost- and resource intensive. This study aims to develop, optimise, and evaluate a gas chromatography-drift tube-ion mobility spectrometry (GC-IMS) based method with a twofold enrichment strategy consisting of solid phase extraction (SPE) followed by in-tube extraction (ITEX) of the eluate for nine different nitrosamines in drinking water in order to offer a sensitive alternative to the current state of the art. Optimisation of ITEX parameters was successfully performed using a simplex self-directing design approach, so that a calibration range between 5 and 50 ng/L could be achieved. The suitability of a linear regression model was demonstrated via analysis of variance (ANOVA) criteria. The analysis of different spiked drinking water samples allowed for the determination of the method’s accuracy (27.3 – 114.5 % across different nitrosamine analytes and matrices, with most above 70 % recovery) and detection limits (1.12 – 12.48 ng/L across different nitrosamine analytes and matrices), which fall within the range of required limit values. Tested drinking waters show innate nitrosamine concentrations well below detection limits and can thus be deemed free from contaminants.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography Open
Published
2025-04-16
DOI
https://doi.org/10.1016/j.jcoa.2025.100220
Citations
1
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
1.20
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development, optimisation, and pre-validation of a gas chromatography—Ion mobility spectrometry method with preliminary twofold enrichment for the sensitive detection of N Nitrosamines in drinking water

Michaela Wirtz, Jana Hinz, Ursula Telgheder, Kaliyani Wickneswaran
1 citations
Journal of Chromatography Open
Water Treatment and Disinfection
1.20
article

Development, optimisation, and pre-validation of a gas chromatography—Ion mobility spectrometry method with preliminary twofold enrichment for the sensitive detection of N Nitrosamines in drinking water

Michaela Wirtz, Jana Hinz, Ursula Telgheder, Kaliyani Wickneswaran
article en
1 citations

Abstract

• Sensitive and selective analysis method for nine N-nitrosamines in drinking waters. • Twofold enrichment via subsequent solid phase extraction and in-tube extraction. • Method development following US EPA guidelines. • Recoveries between 56.1 and 113.6 % for relevant N NOs in drinking water. • Method LODs and LOQs of 1.12 – 12.48 ng/L and 3.35 – 37.44 ng/L, respectively. N Nitrosamines have long been identified as a relevant contaminant in potable water due to their identification as probable human carcinogens. Thus, highly sensitive detection of these pollutants in the ultra-trace range is imperative to comply with strict regulatory specifications. To this end, many institutions rely on mass spectrometry-based analysis methods, which have the disadvantage of being cost- and resource intensive. This study aims to develop, optimise, and evaluate a gas chromatography-drift tube-ion mobility spectrometry (GC-IMS) based method with a twofold enrichment strategy consisting of solid phase extraction (SPE) followed by in-tube extraction (ITEX) of the eluate for nine different nitrosamines in drinking water in order to offer a sensitive alternative to the current state of the art. Optimisation of ITEX parameters was successfully performed using a simplex self-directing design approach, so that a calibration range between 5 and 50 ng/L could be achieved. The suitability of a linear regression model was demonstrated via analysis of variance (ANOVA) criteria. The analysis of different spiked drinking water samples allowed for the determination of the method’s accuracy (27.3 – 114.5 % across different nitrosamine analytes and matrices, with most above 70 % recovery) and detection limits (1.12 – 12.48 ng/L across different nitrosamine analytes and matrices), which fall within the range of required limit values. Tested drinking waters show innate nitrosamine concentrations well below detection limits and can thus be deemed free from contaminants.

Journal of Chromatography OpenVol. 7
Hochschule Bonn-Rhein-Sieg (DE), University of Duisburg-Essen (DE)
Clean water and sanitation
Openalex Percentile: Top 24%
Water Treatment and Disinfection
1.20
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.