RP-UPLC Analytical Method Development For Simultaneous Estimation Ritodrine By Analytical Qbd (Aqbd)) Approach

A simple, Accurate, precise method was developed for the estimation of the Ritodrine in bulk and pharmaceutical dosage form. Chromatogram was run through Hibar100 x 2.1 mm, 2m. Mobile phase containing 0.1N OPA: Acetonitrile taken in the ratio 55(%v/v) and 45 was pumped through column at a flow rate of 0.9 ml/min. Temperature was maintained at 30°C. Optimized wavelength selected was ACQUITY TUV ChA 220.0 nm. Retention time of Ritodrine was found to be 1.065 min. %RSD of the Ritodrine was found to be 1.5. % Recovery was obtained as 99.95% for Ritodrine. Regression equation of Ritodrine is y = 69931x + 4571.9. Retention times were decreased and that run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.  

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2024-11-12
DOI
https://doi.org/10.53555/ajbr.v27i4s.7414
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-UPLC Analytical Method Development For Simultaneous Estimation Ritodrine By Analytical Qbd (Aqbd)) Approach

Kasi Viswanadh Vuyyuri
African Journal of Biomedical Research
Analytical Methods in Pharmaceuticals
article

RP-UPLC Analytical Method Development For Simultaneous Estimation Ritodrine By Analytical Qbd (Aqbd)) Approach

Kasi Viswanadh Vuyyuri
article en

Abstract

A simple, Accurate, precise method was developed for the estimation of the Ritodrine in bulk and pharmaceutical dosage form. Chromatogram was run through Hibar100 x 2.1 mm, 2m. Mobile phase containing 0.1N OPA: Acetonitrile taken in the ratio 55(%v/v) and 45 was pumped through column at a flow rate of 0.9 ml/min. Temperature was maintained at 30°C. Optimized wavelength selected was ACQUITY TUV ChA 220.0 nm. Retention time of Ritodrine was found to be 1.065 min. %RSD of the Ritodrine was found to be 1.5. % Recovery was obtained as 99.95% for Ritodrine. Regression equation of Ritodrine is y = 69931x + 4571.9. Retention times were decreased and that run time was decreased, so the method developed was simple and economical that can be adopted in regular Quality control test in Industries.  

African Journal of Biomedical Research
Openalex Percentile: Top 73%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.