Design and Evaluation of an Integrated Ultra‐High Frequency and Optical Sensor for Partial Discharge Detection in GIS

ABSTRACT Partial discharge (PD) detection is an important technique for monitoring and evaluating the insulation condition of gas‐insulated switchgear (GIS) equipment. The joint analysis and diagnosis of multiple signals can effectively improve the sensitivity and reliability of PD detection. In this paper, an integrated ultra‐high frequency (UHF) and optical sensor is proposed and designed for PD detection. The effectiveness and sensitivity of the designed sensor are experimentally tested. Furthermore, a 500 kV GIS test platform is built, and PD measurements for different types of defects (metal particle on the insulator surface, floating potential, and protrusion) are carried out based on the integrated sensor. The results show that the integrated sensor can detect discharge signals with a minimum apparent charge below 2 pC and has good detection performance for different types of defects. Due to different propagation and attenuation characteristics, there is no strict correspondence between the amplitude of optical and UHF signals. This means that even if the amplitude of the UHF signal is close, the optical signal amplitude may still differ significantly. Compared to UHF signals, the amplitude distribution of optical signals is more dispersed, resulting in differences in the phase‐resolved PD pattern characteristics between optical and UHF signals. Moreover, the effectiveness of the optical method is more easily affected by the sensor and defect position compared to the UHF method, and in some cases, the sensitivity of the optical method is lower than that of the UHF method. The results of this study provide a foundation for a reliable and sensitive PD detection technique in the GIS.

Authors

Institutions

Publication Details

Journal
IET Science Measurement & Technology
Published
2025-01-01
DOI
https://doi.org/10.1049/smt2.70006
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Evaluation of an Integrated Ultra‐High Frequency and Optical Sensor for Partial Discharge Detection in GIS

Dengwei Ding, Xing Li, Zuowei Shen, Mao Li et al.
1 citations
IET Science Measurement & Technology
High voltage insulation and dielectric phenomena
0.52
article

Design and Evaluation of an Integrated Ultra‐High Frequency and Optical Sensor for Partial Discharge Detection in GIS

Dengwei Ding, Xing Li, Zuowei Shen, Mao Li, Wenjia Li, Feng Chen
article en
1 citations

Abstract

ABSTRACT Partial discharge (PD) detection is an important technique for monitoring and evaluating the insulation condition of gas‐insulated switchgear (GIS) equipment. The joint analysis and diagnosis of multiple signals can effectively improve the sensitivity and reliability of PD detection. In this paper, an integrated ultra‐high frequency (UHF) and optical sensor is proposed and designed for PD detection. The effectiveness and sensitivity of the designed sensor are experimentally tested. Furthermore, a 500 kV GIS test platform is built, and PD measurements for different types of defects (metal particle on the insulator surface, floating potential, and protrusion) are carried out based on the integrated sensor. The results show that the integrated sensor can detect discharge signals with a minimum apparent charge below 2 pC and has good detection performance for different types of defects. Due to different propagation and attenuation characteristics, there is no strict correspondence between the amplitude of optical and UHF signals. This means that even if the amplitude of the UHF signal is close, the optical signal amplitude may still differ significantly. Compared to UHF signals, the amplitude distribution of optical signals is more dispersed, resulting in differences in the phase‐resolved PD pattern characteristics between optical and UHF signals. Moreover, the effectiveness of the optical method is more easily affected by the sensor and defect position compared to the UHF method, and in some cases, the sensitivity of the optical method is lower than that of the UHF method. The results of this study provide a foundation for a reliable and sensitive PD detection technique in the GIS.

IET Science Measurement & TechnologyVol. 19(1)
Tsinghua Sichuan Energy Internet Research Institute (CN), Tsinghua University (CN)
Openalex Percentile: Top 40%
High voltage insulation and dielectric phenomena
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.