Electrochemical Catheter Hub Operated by a Wearable Micropotentiostat Prevents <i>Acinetobacter baumannii</i> Infection In Vitro

Intraluminal infection of central venous catheters, used for long-term treatment, can result in central line-associated bloodstream infection (CLABSI). These infections can be challenging to prevent and treat due to formation of biofilms within catheter lumens, which shield bacteria from the human immune response and conventional antimicrobial therapies. Preventing bacterial colonization of catheter hubs is a strategy to prevent CLABSI. To address this, we developed a nonantibiotic, animal-ready electrochemical catheter hub (e-catheter hub), operated by a wearable, battery-powered micropotentiostat (MP), that internally generates tunable hypochlorous acid (HOCl) for preventing intraluminal infection. The design evaluated three different electrode materials-titanium, platinum, and gold-for HOCl generation and biocidal activity, using working and counter electrodes of the same materials and a silver/silver chloride-plated wire as a quasi-reference electrode. e-catheter hubs operated by MPs at 1.5 V<sub>Ag/AgCl</sub> for 3 h generated HOCl, reducing Acinetobacter baumannii ATCC-17978 below the detection limit (average reduction of 4.40 ± 0.05 log<sub>10</sub> CFU/mL). The efficacy of e-catheter hubs operated by MPs in generating HOCl and achieving biocidal activity is comparable to that of a commercial potentiostat. This study represents the first step in developing a localized, nonantibiotic strategy to mitigate CLABSI risk.

Authors

Institutions

Publication Details

Journal
Biotechnology and Bioengineering
Published
2025-04-15
DOI
https://doi.org/10.1002/bit.28990
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Catheter Hub Operated by a Wearable Micropotentiostat Prevents Acinetobacter baumannii Infection In Vitro

Ibrahim Bozyel, Won‐Jun Kim, Haluk Beyenal, Derek Fleming et al.
Biotechnology and Bioengineering
Central Venous Catheters and Hemodialysis
article

Electrochemical Catheter Hub Operated by a Wearable Micropotentiostat Prevents Acinetobacter baumannii Infection In Vitro

Ibrahim Bozyel, Won‐Jun Kim, Haluk Beyenal, Derek Fleming, Robin Patel, Majid Al‐Qurahi
article en

Abstract

Intraluminal infection of central venous catheters, used for long-term treatment, can result in central line-associated bloodstream infection (CLABSI). These infections can be challenging to prevent and treat due to formation of biofilms within catheter lumens, which shield bacteria from the human immune response and conventional antimicrobial therapies. Preventing bacterial colonization of catheter hubs is a strategy to prevent CLABSI. To address this, we developed a nonantibiotic, animal-ready electrochemical catheter hub (e-catheter hub), operated by a wearable, battery-powered micropotentiostat (MP), that internally generates tunable hypochlorous acid (HOCl) for preventing intraluminal infection. The design evaluated three different electrode materials-titanium, platinum, and gold-for HOCl generation and biocidal activity, using working and counter electrodes of the same materials and a silver/silver chloride-plated wire as a quasi-reference electrode. e-catheter hubs operated by MPs at 1.5 V<sub>Ag/AgCl</sub> for 3 h generated HOCl, reducing Acinetobacter baumannii ATCC-17978 below the detection limit (average reduction of 4.40 ± 0.05 log<sub>10</sub> CFU/mL). The efficacy of e-catheter hubs operated by MPs in generating HOCl and achieving biocidal activity is comparable to that of a commercial potentiostat. This study represents the first step in developing a localized, nonantibiotic strategy to mitigate CLABSI risk.

Biotechnology and BioengineeringVol. 122(7)
Worcester Polytechnic Institute (US), Mayo Clinic (US), Mayo Clinic in Florida (US), Washington State University (US)
National Institutes of Health, National Institute of Allergy and Infectious Diseases
Openalex Percentile: Top 87%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.