The Influence of Structural Design on the Electronic Properties of a Frisch Grid Cadmium Zinc Telluride Detector by a Finite Element Method

Cadmium zinc telluride (CZT) detectors have the advantages of high detection efficiency and good energy resolution, which are widely used in the fields of X-ray detection, environmental monitoring and nuclear radiation detection. The Frisch grid structure is used more often in the preparation of detectors because of its good unipolarity and simple structure. In this paper, the effects of changing the gate position, width and relative dielectric constant on the electrical properties of Frisch grid CZT detectors, such as potential, weight potential, electric field distribution and charge collection efficiency, are simulated in detail by the finite element method. From the simulation results, the optimisation of the performance of the Frisch grid detector is mainly based on minimising the distance between the gate and anode within a reasonable interval, increasing the area of the Frisch grid and selecting a material with a high relative permittivity for the fabrication of the Frisch grid. The research work contributes to the development of CZT detectors.

Authors

Institutions

Publication Details

Journal
Crystals
Published
2025-04-15
DOI
https://doi.org/10.3390/cryst15040361
Primary Topic
Advanced Semiconductor Detectors and Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of Structural Design on the Electronic Properties of a Frisch Grid Cadmium Zinc Telluride Detector by a Finite Element Method

Zhenzhao Zhang, Meng Cao, Weifan He, Li Yu et al.
Crystals
Advanced Semiconductor Detectors and Materials
article

The Influence of Structural Design on the Electronic Properties of a Frisch Grid Cadmium Zinc Telluride Detector by a Finite Element Method

Zhenzhao Zhang, Meng Cao, Weifan He, Li Yu, Linjun Wang, Jian Huang, Zhen Xu
article en

Abstract

Cadmium zinc telluride (CZT) detectors have the advantages of high detection efficiency and good energy resolution, which are widely used in the fields of X-ray detection, environmental monitoring and nuclear radiation detection. The Frisch grid structure is used more often in the preparation of detectors because of its good unipolarity and simple structure. In this paper, the effects of changing the gate position, width and relative dielectric constant on the electrical properties of Frisch grid CZT detectors, such as potential, weight potential, electric field distribution and charge collection efficiency, are simulated in detail by the finite element method. From the simulation results, the optimisation of the performance of the Frisch grid detector is mainly based on minimising the distance between the gate and anode within a reasonable interval, increasing the area of the Frisch grid and selecting a material with a high relative permittivity for the fabrication of the Frisch grid. The research work contributes to the development of CZT detectors.

CrystalsVol. 15(4)
Shanghai University (CN), Key Laboratory of Nuclear Radiation and Nuclear Energy Technology (CN), Shanghai Research Institute of Materials (CN), Nanjing Polytechnic Institute (CN)
Shanghai Institute of Technical Physics, Chinese Academy of Sciences
Openalex Percentile: Top 94%
Advanced Semiconductor Detectors and Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.