Establishing the Diagnostic Reference Levels for Common Dubai Health Adult Nuclear Medicine Examinations

Nuclear medicine (NM) procedures are performed using unsealed radioactive sources that are administered to patients, resulting in both internal and external exposure for patients and staff alike. Optimization is mainly concerned with ensuring the use of the lowest sufficient level of radiation to perform a procedure while maintaining adequate image quality. Diagnostic reference levels (DRLs) have been proven effective in aiding optimization in clinical practice. This dose review aims to establish an inclusive DRL system for the common adult NM procedures performed at Dubai Health. Our defined DRLs will focus on both the administered radiopharmaceuticals and the radiation dose metrics derived from hybrid computed tomography (CT). Dose surveys for 1439 adult nuclear medicine procedures performed over twelve months were collected and retrospectively analyzed. DRLs were obtained for a total of eight scintigraphy procedures, four hybrid positron emission tomography procedures with CT (denoted PET/CT), and five target sites for CT hybrid single-photon emission tomography with CT (denoted as SPECT/CT). Our derived DRLs for the scintigraphy, hybrid SPECT/CT and PET/CT procedures are within the reported national DRLs, except for the CT dose of the hybrid SPECT/CT for the neck, abdomen and chest/abdomen sites and the <sup>18</sup>F PSMA administered activity. A fixed activity dose was administered for a scintigraphy procedure that is weight dependent. This patient dose review serves as a foundational effort aiming to optimize radiation safety and standardize diagnostic practices in NM. Further research is needed to enhance adherence to safety benchmarks.

Authors

Institutions

Publication Details

Journal
Life
Published
2025-04-15
DOI
https://doi.org/10.3390/life15040649
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing the Diagnostic Reference Levels for Common Dubai Health Adult Nuclear Medicine Examinations

Entesar Z. Dalah, Z. Ali, Najlaa K. Al Mazrouei
1 citations
Life
Radiation Dose and Imaging
1.36
article

Establishing the Diagnostic Reference Levels for Common Dubai Health Adult Nuclear Medicine Examinations

Entesar Z. Dalah, Z. Ali, Najlaa K. Al Mazrouei
article en
1 citations

Abstract

Nuclear medicine (NM) procedures are performed using unsealed radioactive sources that are administered to patients, resulting in both internal and external exposure for patients and staff alike. Optimization is mainly concerned with ensuring the use of the lowest sufficient level of radiation to perform a procedure while maintaining adequate image quality. Diagnostic reference levels (DRLs) have been proven effective in aiding optimization in clinical practice. This dose review aims to establish an inclusive DRL system for the common adult NM procedures performed at Dubai Health. Our defined DRLs will focus on both the administered radiopharmaceuticals and the radiation dose metrics derived from hybrid computed tomography (CT). Dose surveys for 1439 adult nuclear medicine procedures performed over twelve months were collected and retrospectively analyzed. DRLs were obtained for a total of eight scintigraphy procedures, four hybrid positron emission tomography procedures with CT (denoted PET/CT), and five target sites for CT hybrid single-photon emission tomography with CT (denoted as SPECT/CT). Our derived DRLs for the scintigraphy, hybrid SPECT/CT and PET/CT procedures are within the reported national DRLs, except for the CT dose of the hybrid SPECT/CT for the neck, abdomen and chest/abdomen sites and the <sup>18</sup>F PSMA administered activity. A fixed activity dose was administered for a scintigraphy procedure that is weight dependent. This patient dose review serves as a foundational effort aiming to optimize radiation safety and standardize diagnostic practices in NM. Further research is needed to enhance adherence to safety benchmarks.

LifeVol. 15(4)
Dubai Hospital (AE), Mohammed Bin Rashid University of Medicine and Health Sciences (AE)
Good health and well-being
Openalex Percentile: Top 21%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Establishing the Diagnostic Reference Levels for Common Dubai Health Adult Nuclear Medicine Examinations — Entesar Z. Dalah, Z. Ali, et al. · Life (2025) | TGRS Research Map | TGRS