Determination of Crack Tip Plastic Zone Using Dynamically Visible Mechanochromic Luminescence Response

The plastic zone shields the crack tip from high stress and plays an important role in the fracture of structures. Determination of the plastic zone is a significant challenge in large-scale and complex structures. In the present work, a detection method using mechanochromic luminescent (MCL) sensing film has been proposed to detect the plastic zone near the crack tip. The deformation near the crack tip is converted into visible green fluorescence emission. A comprehensive post-processing protocol and a feature quantification scheme for fluorescence images are introduced. A significant correlation is obtained between the characteristic values of fluorescence images and the parameters of the plastic zone (i.e., maximum equivalent strain and plastic zone size), indicating that the fluorescence response provides effective characterization parameters within the forward model. The plastic zone parameters determined using the MRL-based method agree well with the results measured using the DIC method. This indicates that the plastic zone near the crack tip can be effectively analyzed by capturing loading conditions and fluorescence response.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-04-15
DOI
https://doi.org/10.3390/ma18081810
Citations
2
Primary Topic
Luminescence and Fluorescent Materials
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Crack Tip Plastic Zone Using Dynamically Visible Mechanochromic Luminescence Response

Zhe Zhang, Yonggang Ren, Yuhan Tong
2 citations
Materials
Luminescence and Fluorescent Materials
1.04
article

Determination of Crack Tip Plastic Zone Using Dynamically Visible Mechanochromic Luminescence Response

Zhe Zhang, Yonggang Ren, Yuhan Tong
article en
2 citations

Abstract

The plastic zone shields the crack tip from high stress and plays an important role in the fracture of structures. Determination of the plastic zone is a significant challenge in large-scale and complex structures. In the present work, a detection method using mechanochromic luminescent (MCL) sensing film has been proposed to detect the plastic zone near the crack tip. The deformation near the crack tip is converted into visible green fluorescence emission. A comprehensive post-processing protocol and a feature quantification scheme for fluorescence images are introduced. A significant correlation is obtained between the characteristic values of fluorescence images and the parameters of the plastic zone (i.e., maximum equivalent strain and plastic zone size), indicating that the fluorescence response provides effective characterization parameters within the forward model. The plastic zone parameters determined using the MRL-based method agree well with the results measured using the DIC method. This indicates that the plastic zone near the crack tip can be effectively analyzed by capturing loading conditions and fluorescence response.

MaterialsVol. 18(8)
Tianjin University (CN), Tianjin Special Equipment Supervision and Inspection Technology Research Institute (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 26%
Luminescence and Fluorescent Materials
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of Crack Tip Plastic Zone Using Dynamically Visible Mechanochromic Luminescence Response — Zhe Zhang, Yonggang Ren, et al. · Materials (2025) | TGRS Research Map | TGRS