Numerical simulation study for double pipe heat exchanger with spiral fins

Abstract The aim of the presented is to investigate the effects of different helical fin pitches (20, 40, and 60 mm) on the performance of helical fins on inner tube outer surface. With an outer tube diameter of 65–75 mm, an inner tube diameter of 25–35 mm, and a length of 400 mm, water was used as the heat exchange fluid. The cold fluid entered the inner tube at a 20 °C temperature, with a Reynolds number ranging from 3,000 to 10,000. The hot fluid flowed through the annular space between the two tubes at a constant rate. The study utilized numerical simulation in ANSYS FLUENT v.21 software. The inner pipe was constructed of aluminum, while the outer pipe was insulated. The numerical results indicated that heat transfer and thermal performance initially increased and then decreased as the pitch of the helical fins increased.

Authors

Institutions

Publication Details

Journal
Pollack Periodica
Published
2025-04-15
DOI
https://doi.org/10.1556/606.2024.01229
Citations
1
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical simulation study for double pipe heat exchanger with spiral fins

Duraid Majeed Mutar
1 citations
Pollack Periodica
Heat Transfer and Optimization
0.71
article

Numerical simulation study for double pipe heat exchanger with spiral fins

Duraid Majeed Mutar
article en
1 citations

Abstract

Abstract The aim of the presented is to investigate the effects of different helical fin pitches (20, 40, and 60 mm) on the performance of helical fins on inner tube outer surface. With an outer tube diameter of 65–75 mm, an inner tube diameter of 25–35 mm, and a length of 400 mm, water was used as the heat exchange fluid. The cold fluid entered the inner tube at a 20 °C temperature, with a Reynolds number ranging from 3,000 to 10,000. The hot fluid flowed through the annular space between the two tubes at a constant rate. The study utilized numerical simulation in ANSYS FLUENT v.21 software. The inner pipe was constructed of aluminum, while the outer pipe was insulated. The numerical results indicated that heat transfer and thermal performance initially increased and then decreased as the pitch of the helical fins increased.

Pollack PeriodicaVol. 20(2)
Middle Technical University (IQ)
Openalex Percentile: Top 34%
Heat Transfer and Optimization
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.