Detect and Minimize Reverse Power Flow in a Renewable Energy Distribution System

High permeability of renewable energy into the power system can cause risks such as overvoltage, frequency variation, voltage deviation, reverse power flow (RPF), etc. This paper presents a method to detect and minimize the reverse power flow in a distribution system integrated with renewable energy. IEEE 13 bus with a monitor is mounted on the source bus to identify the reverse power flow used to test the system. To demonstrate the induction of reverse power flow, a PV system is connected at node 611 with a set capacity of 4000 kW. The load flow is performed using co-simulation between engines OpenDSS and MATLAB through component object model server dynamiclink library. Biogeography-based optimization (BBO) is applied to solve the multiple objective functions, including RPF at the substation and total load increase at each bus. Combining BBO and PSO can balance both global and local search capabilities. Results obtained by the proposed method show that the reverse power flow at the substation occurring due to the connection of large amounts of renewable energy sources can be significantly reduced.

Authors

Institutions

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1109/iceaai64185.2025.10957678
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detect and Minimize Reverse Power Flow in a Renewable Energy Distribution System

Yanchi Zhang, Yi Chen, Yunfeng Bi
Optimal Power Flow Distribution
article

Detect and Minimize Reverse Power Flow in a Renewable Energy Distribution System

Yanchi Zhang, Yi Chen, Yunfeng Bi
article en

Abstract

High permeability of renewable energy into the power system can cause risks such as overvoltage, frequency variation, voltage deviation, reverse power flow (RPF), etc. This paper presents a method to detect and minimize the reverse power flow in a distribution system integrated with renewable energy. IEEE 13 bus with a monitor is mounted on the source bus to identify the reverse power flow used to test the system. To demonstrate the induction of reverse power flow, a PV system is connected at node 611 with a set capacity of 4000 kW. The load flow is performed using co-simulation between engines OpenDSS and MATLAB through component object model server dynamiclink library. Biogeography-based optimization (BBO) is applied to solve the multiple objective functions, including RPF at the substation and total load increase at each bus. Combining BBO and PSO can balance both global and local search capabilities. Results obtained by the proposed method show that the reverse power flow at the substation occurring due to the connection of large amounts of renewable energy sources can be significantly reduced.

Shanghai Dianji University (CN)
Affordable and clean energy
Openalex Percentile: Top 94%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detect and Minimize Reverse Power Flow in a Renewable Energy Distribution System — Yanchi Zhang, Yi Chen, et al. · (2025) | TGRS Research Map | TGRS