Temperature Distribution Measurement and Simulation of Transmission Line Arrester Under Impulse Voltage

Arrester is an important protection device for transmission lines. Due to the complex weather conditions and harsh operating environment, line arrester failures occur from time to time, affecting the normal operation of the power system. In this paper, a fluorescence optical fiber temperature measurement system for line arresters is built. The temperature changes of zinc oxide valve plates at different positions under two operating conditions of continuous operating voltage and switching impulse overvoltage are studied. The finite element simulation model of line arrester is established, and the electro-thermal coupling simulation of arrester is carried out. The calculation results are in good agreement with the test results. The valve plate defects are set in the simulation model, and the influence of defect position and defect number on the temperature distribution characteristics of arrester is studied.

Authors

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1109/iceaai64185.2025.10957558
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature Distribution Measurement and Simulation of Transmission Line Arrester Under Impulse Voltage

Kai Cheng, Jun Fu, Zhenxing Zhang, Bing Han
High-Voltage Power Transmission Systems
article

Temperature Distribution Measurement and Simulation of Transmission Line Arrester Under Impulse Voltage

Kai Cheng, Jun Fu, Zhenxing Zhang, Bing Han
article en

Abstract

Arrester is an important protection device for transmission lines. Due to the complex weather conditions and harsh operating environment, line arrester failures occur from time to time, affecting the normal operation of the power system. In this paper, a fluorescence optical fiber temperature measurement system for line arresters is built. The temperature changes of zinc oxide valve plates at different positions under two operating conditions of continuous operating voltage and switching impulse overvoltage are studied. The finite element simulation model of line arrester is established, and the electro-thermal coupling simulation of arrester is carried out. The calculation results are in good agreement with the test results. The valve plate defects are set in the simulation model, and the influence of defect position and defect number on the temperature distribution characteristics of arrester is studied.

Science and Technology Project of State Grid
Affordable and clean energy
Openalex Percentile: Top 94%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.