Research on the Distinction Method of Partial Discharge Inside and Outside the Windings of 110 kV Transformer in Early Operation

This paper presents a method to distinguish partial discharge inside and outside transformer windings using online dissolved gas analysis and acetylene concentration measurement in 110 kV oil-immersed self-cooled transformers during early operation. A finite element model of the transformer is built, and four typical locations prone to partial discharge are selected to simulate acetylene diffusion. Results show that when partial discharge occurs within windings, the time for acetylene concentration to reach the alarm value increases from top to bottom detection points. However, no clear pattern is observed for discharges outside the windings. Acetylene concentration peaks, steady-state values, and differences increase as detection points get closer.

Authors

Institutions

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1109/iceaai64185.2025.10956884
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Distinction Method of Partial Discharge Inside and Outside the Windings of 110 kV Transformer in Early Operation

J.T.-Y. Chang, Xing Tang
High-Voltage Power Transmission Systems
article

Research on the Distinction Method of Partial Discharge Inside and Outside the Windings of 110 kV Transformer in Early Operation

J.T.-Y. Chang, Xing Tang
article en

Abstract

This paper presents a method to distinguish partial discharge inside and outside transformer windings using online dissolved gas analysis and acetylene concentration measurement in 110 kV oil-immersed self-cooled transformers during early operation. A finite element model of the transformer is built, and four typical locations prone to partial discharge are selected to simulate acetylene diffusion. Results show that when partial discharge occurs within windings, the time for acetylene concentration to reach the alarm value increases from top to bottom detection points. However, no clear pattern is observed for discharges outside the windings. Acetylene concentration peaks, steady-state values, and differences increase as detection points get closer.

Zhengzhou University (CN)
Affordable and clean energy
Openalex Percentile: Top 94%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.