Application and Analysis of Automatic Tuning Arc Suppression Coil in Power Grid

This paper describes the importance of auto-tuned arc suppression coil in power grid operation. Compared with the traditional arc suppression coil which relied on manual adjustment, automatic tracking arc suppression coil is convenient to adjust and accurate to select the gear during operation. It can avoid the formation of series resonance with full compensation after line tripping and overcome the previous shortcomings [1]. Through theoretical analysis, the addition of damping resistance can reduce the neutral point displacement voltage, and the suitable damping resistance value is calculated theoretically, and applied in practical cases, so that the neutral point voltage of 66kV north bus line of DD 220kV substation can be reduced to the ideal value, eliminating the false grounding, system resonance and other faults caused by excessive neutral point displacement voltage, and improving the power supply quality. It also provides a reference for the wide application of auto-tuned arc suppression coil in power grid.

Authors

Institutions

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1109/iceaai64185.2025.10957097
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application and Analysis of Automatic Tuning Arc Suppression Coil in Power Grid

Huabin Xing, Hong Huo, Fucheng Sun, Lan-Hang Chen et al.
Power Systems and Technologies
article

Application and Analysis of Automatic Tuning Arc Suppression Coil in Power Grid

Huabin Xing, Hong Huo, Fucheng Sun, Lan-Hang Chen, Guangqi Liu, Junliang Liu, Puqing Liu, E Shengjun
article en

Abstract

This paper describes the importance of auto-tuned arc suppression coil in power grid operation. Compared with the traditional arc suppression coil which relied on manual adjustment, automatic tracking arc suppression coil is convenient to adjust and accurate to select the gear during operation. It can avoid the formation of series resonance with full compensation after line tripping and overcome the previous shortcomings [1]. Through theoretical analysis, the addition of damping resistance can reduce the neutral point displacement voltage, and the suitable damping resistance value is calculated theoretically, and applied in practical cases, so that the neutral point voltage of 66kV north bus line of DD 220kV substation can be reduced to the ideal value, eliminating the false grounding, system resonance and other faults caused by excessive neutral point displacement voltage, and improving the power supply quality. It also provides a reference for the wide application of auto-tuned arc suppression coil in power grid.

Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 94%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application and Analysis of Automatic Tuning Arc Suppression Coil in Power Grid — Huabin Xing, Hong Huo, et al. · (2025) | TGRS Research Map | TGRS