Analysis of Grounding Fault of Overhead Broken Line in Distribution Network

In the medium and low power distribution system of 6-66kV, the single-phase broken line grounding fault of overhead line often occurs, which endangers personal safety and affects the normal operation of power load. Under the premise of considering the nature of the load on the grounding point, the current and voltage of the protection installation point, the broken point, the grounding point and the load side when the single-phase broken line grounding fault in power distribution system with neutral non-effectively grounded are analyzed, and the calculation formula of the voltage and current at each point is derived. The analysis results shows that the voltage of protection installation, grounding point and load side is related to load properties and transition resistance. The voltage at the broken point is related to the load properties. In this paper, a real distribution network grounding fault is analyzed, focusing on the grounding protection action and fault disposal.

Authors

Institutions

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1109/iceaai64185.2025.10957106
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Grounding Fault of Overhead Broken Line in Distribution Network

Zhiyu Zhao, Yu Cui, Siyuan Liu, Weilin Liu et al.
Power Systems Fault Detection
article

Analysis of Grounding Fault of Overhead Broken Line in Distribution Network

Zhiyu Zhao, Yu Cui, Siyuan Liu, Weilin Liu, Yajuan Wang, Tianle Liang
article en

Abstract

In the medium and low power distribution system of 6-66kV, the single-phase broken line grounding fault of overhead line often occurs, which endangers personal safety and affects the normal operation of power load. Under the premise of considering the nature of the load on the grounding point, the current and voltage of the protection installation point, the broken point, the grounding point and the load side when the single-phase broken line grounding fault in power distribution system with neutral non-effectively grounded are analyzed, and the calculation formula of the voltage and current at each point is derived. The analysis results shows that the voltage of protection installation, grounding point and load side is related to load properties and transition resistance. The voltage at the broken point is related to the load properties. In this paper, a real distribution network grounding fault is analyzed, focusing on the grounding protection action and fault disposal.

State Grid Corporation of China (China) (CN), Inner Mongolia Electric Power (China) (CN)
Climate action
Openalex Percentile: Top 92%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Grounding Fault of Overhead Broken Line in Distribution Network — Zhiyu Zhao, Yu Cui, et al. · (2025) | TGRS Research Map | TGRS