Research on Fault-Tolerant Dual Active Bridge Converter Based on Half-Bridge Multiplexing

In this paper, based on the research background of the voltage instability phenomenon generated by the possible device failures and the serious imbalance of sunshine in the high-latitude cold region of photovoltaic power generation, a topology study of fault-tolerant dual active bridge converter based on half-bridge multiplexing is proposed, which can realize the stable output in the wide range of voltage inputs and part of the device failures, and has the effect of maintaining the stability of grid voltage and improving the power quality of DC power grid. The proposed converter can realize stable output even under a wide range of voltage inputs and some device failures to maintain the stability of grid voltage and improve the power quality of DC network. In this paper, the modal analysis of the proposed converter is carried out, and the fault conditions are analyzed, and the circuit characterization and simulation verification are completed to prove the accuracy of the theoretical analysis.

Authors

Institutions

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1109/iceaai64185.2025.10956417
Primary Topic
Engineering and Test Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Fault-Tolerant Dual Active Bridge Converter Based on Half-Bridge Multiplexing

Yufei Guo, Dianguo Xu, Yiliang Li, Qian Wu et al.
Engineering and Test Systems
article

Research on Fault-Tolerant Dual Active Bridge Converter Based on Half-Bridge Multiplexing

Yufei Guo, Dianguo Xu, Yiliang Li, Qian Wu, Baihui Yuan, Yijie Wang
article en

Abstract

In this paper, based on the research background of the voltage instability phenomenon generated by the possible device failures and the serious imbalance of sunshine in the high-latitude cold region of photovoltaic power generation, a topology study of fault-tolerant dual active bridge converter based on half-bridge multiplexing is proposed, which can realize the stable output in the wide range of voltage inputs and part of the device failures, and has the effect of maintaining the stability of grid voltage and improving the power quality of DC power grid. The proposed converter can realize stable output even under a wide range of voltage inputs and some device failures to maintain the stability of grid voltage and improve the power quality of DC network. In this paper, the modal analysis of the proposed converter is carried out, and the fault conditions are analyzed, and the circuit characterization and simulation verification are completed to prove the accuracy of the theoretical analysis.

Harbin Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 92%
Engineering and Test Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Fault-Tolerant Dual Active Bridge Converter Based on Half-Bridge Multiplexing — Yufei Guo, Dianguo Xu, et al. · (2025) | TGRS Research Map | TGRS