Noniterative Wet Gas Flow Metering in Annular Mist Flow by Combining Vortex Meter and Liquid Film Parameters

Wet gas metering in annular mist flow is important for it is typically used in fiscal metering, and the traditional iteration-based methods are limited due to their sensitivity to initial values and time-consuming in the iteration process. To improve the real-time performance and reliability, this study tries to develop non-iterative wet gas metering method based on the vortex meter-conductance dual-modality system. To adapt to different application scenarios, two models are proposed, named non-linear regression model and neural network model, respectively. The tests are conducted on a DN 15 vertical pipeline with a gas flow rate range of 12-24 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup>/h and liquid volume fraction within 1.3‰. To obtain the flow parameters of liquid film thickness, disturbance wave frequency and velocity simultaneously, the dual-ring liquid film sensor is designed and optimized. The input features are selected by the importance ranking of the correlation heatmap, and the optimized hyperparameters and K-fold cross-validation ensure the generalization of the trained neural network. Finally, the predicted performances are evaluated and compared in detail. It indicates that mean film thickness could be regarded as the unique scale parameter of vortex meter overreading, and Eq. (11) gives a predicted error of ±1.5% for gas flow rate. Liquid flow could be directly predicted by combining different liquid film flow parameters, and Eq. (15) gives a predicted full-scale error of ±5.0% for liquid flow rate. The neural network model gives satisfactory prediction both for gas and liquid flow rates, gas flow accuracy within ±1.0% error bands, and liquid flow within ±1.5% full-scale error bands. Finally, comparisons and practical suggestions for the application are given for the two proposed non-iterative wet gas metering models.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3560723
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noniterative Wet Gas Flow Metering in Annular Mist Flow by Combining Vortex Meter and Liquid Film Parameters

Hongjun Sun, Hongbing Ding, Jinxia Li, Yi Huang et al.
IEEE Transactions on Instrumentation and Measurement
Flow Measurement and Analysis
article

Noniterative Wet Gas Flow Metering in Annular Mist Flow by Combining Vortex Meter and Liquid Film Parameters

Hongjun Sun, Hongbing Ding, Jinxia Li, Yi Huang, Ji Lin
article en

Abstract

Wet gas metering in annular mist flow is important for it is typically used in fiscal metering, and the traditional iteration-based methods are limited due to their sensitivity to initial values and time-consuming in the iteration process. To improve the real-time performance and reliability, this study tries to develop non-iterative wet gas metering method based on the vortex meter-conductance dual-modality system. To adapt to different application scenarios, two models are proposed, named non-linear regression model and neural network model, respectively. The tests are conducted on a DN 15 vertical pipeline with a gas flow rate range of 12-24 m<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup>/h and liquid volume fraction within 1.3‰. To obtain the flow parameters of liquid film thickness, disturbance wave frequency and velocity simultaneously, the dual-ring liquid film sensor is designed and optimized. The input features are selected by the importance ranking of the correlation heatmap, and the optimized hyperparameters and K-fold cross-validation ensure the generalization of the trained neural network. Finally, the predicted performances are evaluated and compared in detail. It indicates that mean film thickness could be regarded as the unique scale parameter of vortex meter overreading, and Eq. (11) gives a predicted error of ±1.5% for gas flow rate. Liquid flow could be directly predicted by combining different liquid film flow parameters, and Eq. (15) gives a predicted full-scale error of ±5.0% for liquid flow rate. The neural network model gives satisfactory prediction both for gas and liquid flow rates, gas flow accuracy within ±1.0% error bands, and liquid flow within ±1.5% full-scale error bands. Finally, comparisons and practical suggestions for the application are given for the two proposed non-iterative wet gas metering models.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Tianjin University (CN), Civil Aviation University of China (CN)
National Natural Science Foundation of China
Climate action
Openalex Percentile: Top 92%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.