Weighted Iterative Complex Demodulation for High-Resolution Instantaneous Frequencies in Low-Frequency PPG Signals From Wearable Devices

In this study, we present the development and validation of an advanced signal processing algorithm, weighted iterative time-frequency complex demodulation (wi-TFCD), designed to enhance noise suppression and improve time-frequency resolution in low-frequency physiological signals. We evaluate wi-TFCD against traditional methods such as short-time Fourier transform (STFT), variable frequency complex demodulation (VFCDM), and the baseline iterative TFCD (i-TFCD), using both synthetic chirp signals contaminated with additive Gaussian white noise and real-world photoplethysmography (PPG) signals recorded during exercise. The results demonstrate that wi-TFCD consistently outperforms the other methods, achieving the lowest Rényi entropy and the highest Stanković concentration, which correspond to improved spectral compactness and clarity. For a sinusoidal chirp signal, wi-TFCD achieves a Rényi entropy that is 1.29 times lower than VFCDM and 1.27 times lower than i-TFCD, a Stanković concentration 3.62 times higher than VFCDM and 3.01 times higher than i-TFCD, and a mean square error (MSE) that is 1.29 times lower than VFCDM and 1.11 times lower than i-TFCD, demonstrating superior resolution and robustness under noise. In PPG-based heart rate (HR) estimation across 55 subjects, wi-TFCD achieves a mean absolute error (MAE) of 4.99 bpm, compared to 5.19 bpm for i-TFCD and 5.42 bpm for VFCDM. These findings confirm that wi-TFCD provides more precise signal representation and robust physiological monitoring, making it a promising tool for wearable health applications where motion artifacts and noise are prevalent.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-04-15
DOI
https://doi.org/10.1109/jbhi.2025.3561323
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Weighted Iterative Complex Demodulation for High-Resolution Instantaneous Frequencies in Low-Frequency PPG Signals From Wearable Devices

Dong Keon Yon, Jina Kim, Woocheol Jang, Seung‐Seok Lee et al.
IEEE Journal of Biomedical and Health Informatics
Non-Invasive Vital Sign Monitoring
article

Weighted Iterative Complex Demodulation for High-Resolution Instantaneous Frequencies in Low-Frequency PPG Signals From Wearable Devices

Dong Keon Yon, Jina Kim, Woocheol Jang, Seung‐Seok Lee, So‐Young Lee, Jinseok Lee
article en

Abstract

In this study, we present the development and validation of an advanced signal processing algorithm, weighted iterative time-frequency complex demodulation (wi-TFCD), designed to enhance noise suppression and improve time-frequency resolution in low-frequency physiological signals. We evaluate wi-TFCD against traditional methods such as short-time Fourier transform (STFT), variable frequency complex demodulation (VFCDM), and the baseline iterative TFCD (i-TFCD), using both synthetic chirp signals contaminated with additive Gaussian white noise and real-world photoplethysmography (PPG) signals recorded during exercise. The results demonstrate that wi-TFCD consistently outperforms the other methods, achieving the lowest Rényi entropy and the highest Stanković concentration, which correspond to improved spectral compactness and clarity. For a sinusoidal chirp signal, wi-TFCD achieves a Rényi entropy that is 1.29 times lower than VFCDM and 1.27 times lower than i-TFCD, a Stanković concentration 3.62 times higher than VFCDM and 3.01 times higher than i-TFCD, and a mean square error (MSE) that is 1.29 times lower than VFCDM and 1.11 times lower than i-TFCD, demonstrating superior resolution and robustness under noise. In PPG-based heart rate (HR) estimation across 55 subjects, wi-TFCD achieves a mean absolute error (MAE) of 4.99 bpm, compared to 5.19 bpm for i-TFCD and 5.42 bpm for VFCDM. These findings confirm that wi-TFCD provides more precise signal representation and robust physiological monitoring, making it a promising tool for wearable health applications where motion artifacts and noise are prevalent.

IEEE Journal of Biomedical and Health InformaticsVol. 29(10)
Samsung (South Korea) (KR), Kyung Hee University (KR), Kyung Hee University Medical Center (KR)
Openalex Percentile: Top 93%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.