An Unsupervised Approach to Power Transformer Early Fault Warning Based on PMCAEN and SVDD

Early fault warning is critical for long-term stable operation of power transformer. However, slight mechanical fault of the power transformer does not lead to obvious changes in the vibration signal, which undoubtedly increases the difficulty of early warning. To solve this problem, this article proposes an early fault warning scheme for power transformer using vibration signal. Specifically, a new unsupervised learning framework, parallel multiscale convolutional autoencoder network (PMCAEN), is first developed to capture multidimensional and multiscale feature information of power transformer. Subsequently, support vector data description is established, and the reconstruction error obtained by PMCAEN under normal conditions is used as new observation information to construct the judgment domain of degraded state. The effectiveness of the proposed method is verified by the data collected from a 220-kV power transformer. The experimental results show that the proposed method achieves higher early warning accuracy with respect to the compared algorithms.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Informatics
Published
2025-04-15
DOI
https://doi.org/10.1109/tii.2025.3552721
Primary Topic
Advanced Decision-Making Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Unsupervised Approach to Power Transformer Early Fault Warning Based on PMCAEN and SVDD

Chenran Zhang, Wenyue Li, Zhikai Xing, Yigang He et al.
IEEE Transactions on Industrial Informatics
Advanced Decision-Making Techniques
article

An Unsupervised Approach to Power Transformer Early Fault Warning Based on PMCAEN and SVDD

Chenran Zhang, Wenyue Li, Zhikai Xing, Yigang He, Yazhong Zhou, Kaixuan Shao, Liulu He, Lei Wang
article en

Abstract

Early fault warning is critical for long-term stable operation of power transformer. However, slight mechanical fault of the power transformer does not lead to obvious changes in the vibration signal, which undoubtedly increases the difficulty of early warning. To solve this problem, this article proposes an early fault warning scheme for power transformer using vibration signal. Specifically, a new unsupervised learning framework, parallel multiscale convolutional autoencoder network (PMCAEN), is first developed to capture multidimensional and multiscale feature information of power transformer. Subsequently, support vector data description is established, and the reconstruction error obtained by PMCAEN under normal conditions is used as new observation information to construct the judgment domain of degraded state. The effectiveness of the proposed method is verified by the data collected from a 220-kV power transformer. The experimental results show that the proposed method achieves higher early warning accuracy with respect to the compared algorithms.

IEEE Transactions on Industrial InformaticsVol. 21(7)
Wuhan University (CN), Wuhan Textile University (CN), Nanjing University (CN)
Climate action
Openalex Percentile: Top 91%
Advanced Decision-Making Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.